Plan Review Notes For Permit 20100911 |
Permit Number |
20100911 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2020-10-22 09:19:08 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) THE REVISION TO SHEET AE407 TO REPLACE THE WALL HUNG | | LAVATORIES WITH VANITIES IN RESTROOMS 268 AND 269 | | APPEARS TO CAUSE AN ISSUE. THE VANITIES APPEAR TO | | ENCROACH INTO THE REQUIRED MINIMUM 60" DIAMETER TURNING | | SPACE WITHOUT ALLOWING FOR KNEE AND TOE CLEARANCE. FBC | | ACCESSIBILITY 603 | | | | 2) THE REVISION TO SHEET AE404 IS TO REPLACE THE WALL | | HUNG LAVATORIES WITH VANITIES IN RESTROOMS E135 AND | | E136. SHOW THE REQUIRED CLEARANCES AT THE PLUMBING | | FIXTURES AND THE TURNING SPACE IN THE REVISED RESTROOMS | | ON SHEET AE404. FBC ACCESSIBILITY 603 | | | | 3) WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A | | RESPONSE LETTER ADDRESSING EACH ITEM ALONG WITH THE | | CITY RE-SUBMITTAL FORM. |
|