Date |
Text |
2020-10-20 08:08:21 | 1ST REVIEW FBC-2017 RES. FUEL GAS |
| PERMIT- 20100815 |
| 10/20/2020 |
| |
| CODES IN EFFECT: |
| |
| FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| EDITION 2017 |
| FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| 2017 |
| FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| EDITION 2017 |
| |
| PLAN REVIEW RESULTS: DENIED. |
| |
| 1) GAS RISER DRAWING: THE MAIN 1 IN. GALVANIZED SUPPLY |
| PIPE FROM THE METER TO THE TEE IS UNDERSIZED BASED ON A |
| 12 IN. W.C. SYSTEM AND THE PIPE SIZING YOU ARE SHOWING- |
| TABLE 402.4(3) FBC FG. ACCORDING TO THE TABLE A 1 IN. |
| PIPE WILL PROVIDE A MAXIMUM 456,000 BTU'S AT 125 FT. |
| LENGTH WHICH IS THE LENGTH OF THE UNDERGROUND RUN TO |
| THE POOL HEATER AND GENERATOR. THE ACTUAL DEVELOPED |
| LENGTH OF THE SYSTEM HAS NOT BEEN PROVIDED, PLEASE |
| PROVIDE IT- SECTIONS G2413.4.1 AND G2413.4.2 FBC RES. |
| PLEASE NOTE THE ORIGINAL APPROVED RISER DRAWING UNDER |
| PERMIT- 20061518 SHOWED A 2 PSI SYSTEM. |
| |
| A) THE 1-1/2 IN. PE SUPPLYING THE POOL HEATER AND |
| GENERATOR IS UNDERSIZED BASED ON THE PIPE SIZING TABLE |
| YOU ARE SHOWING- TABLE 402.4(21) FBC FG. ACCORDING TO |
| THE TABLE A 1-1/2 IN. PE WILL SUPPLY A MAXIMUM 485,000 |
| BTU'S AT 125 FT. LENGTH. |
| |
| 2) THE SURVEY DRAWING IS INCORRECTLY INDICATING A 5 FT. |
| CLEARANCE FROM THE GENERATOR TO WINDOW AND DOOR |
| OPENINGS INTO THE BUILDING, HOWEVER A 10 FT. CLEARANCE |
| IS REQUIRED- SECTION R303.5.1 FBC RES. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |
| CHRISTOPHER L. COLE |
| MECHANICAL/PLUMBING PLANS EXAMINER |
| 401 CLEMATIS STREET |
| WEST PALM BEACH FL 33401 |
| 561-805-6719 |
| [email protected] |
| |