2020-10-28 15:43:13 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT A SITE PLAN SHOWING THE LOCATION OF THE | | BUILDING AND THE LOCATION THAT THE SIGN WILL BE | | INSTALLED ON THE BUILDING. FBC 107.2.1 | | | | 2) SUBMIT SIGNED AND SEALED WIND DESIGN DATA AND SIGN | | ANCHORING CALCULATIONS AND DETAILS FROM A LICENSED | | FLORIDA ENGINEER. FBC 1609 | | | | 3) THE VALUE FOR THIS SIGN AND INSTALLATION IS LOW. | | SUBMIT A COPY OF THE CONTRACT WITH THE SCOPE OF WORK IN | | ORDER TO VERIFY THE COSTS. FBC 109.3 |
|