2020-10-23 15:39:57 | NEW SFR |
| REVIEWED BY ROGER MCPHERSON |
| 561-805-6716 |
| [email protected]. |
| CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1 |
| AMENDMENTS |
| |
| CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 |
| 1) PLEASE SHOW AT LEAST 1 BATHROOM DOOR WIDTH TO COMPLY |
| WITH FBC R320.1.1 ALL NEW SINGLE-FAMILY HOUSES, |
| DUPLEXES, TRIPLEXES, CONDOMINIUMS AND TOWNHOUSES SHALL |
| PROVIDE AT LEAST ONE BATHROOM, LOCATED WITH MAXIMUM |
| POSSIBLE PRIVACY, WHERE BATHROOMS ARE PROVIDED ON |
| HABITABLE GRADE LEVELS, WITH A DOOR THAT HAS A 29-INCH |
| (737 MM) CLEAR OPENING. FBC ACCESSIBILITY 404.2.3 CLEAR |
| OPENINGS OF DOORWAYS WITH SWINGING DOORS SHALL BE |
| MEASURED BETWEEN THE FACE OF THE DOOR AND THE STOP, |
| WITH THE DOOR OPEN 90 DEGREES. ( A 2'6" DOOR DOES NOT |
| COMPLY) |
| 2) PLEASE SHOW THE ATTIC ACCESS LOCATION AND SIZE TO |
| COMPLY WITH FBC R807 |
| 3) PLEASE SHOW THE ATTIC VENTILATION TO COMPLY WITH FBC |
| R806 |
| 4) PLEASE SHOW THE BUILDING SQUARE FOOTAGE ON THE |
| DRAWING. |
| 5) ALL DRAWINGS NEED TO BE SIGNED AND SEALED BY THE |
| ARCHITECT OR ENGINEER. FBC 107.1 |
| 6) PLEASE PROVIDE THE FRONT PAGES (MIAMI DADE OR |
| FLORIDA STATE) FOR THE DOOR PRODUCT APPROVAL. |
| (INSTALLATION INSTRUCTIONS HAVE BEEN PROVIDED). |
| 7) PLEASE PROVIDE A SIGNED AND SEALED SURVEY SHOWING |
| THE FOLLOWING INFORMATION 107.2.5 SITE PLAN. THE |
| CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION |
| FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING |
| TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND |
| EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT |
| LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED |
| FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE |
| AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND |
| DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN |
| ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY |
| LINE SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY |
| PROPOSED WATER RETAINING SWALES) |
| |
| |
| |