2020-10-09 16:50:171ST REVIEW FBC-2017 RES. FUEL GAS
 PERMIT- 20100372
 10/9/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) GAS RISER DRAWING: RECORDS RESEARCH FOR 2751 S
 FLAGLER DR. INDICATES A 120,000 BTUH GAS RANGE ISSUED
 UNDER PERMIT- 06061405. PLEASE PROVIDE A COMPLETE RISER
 DRAWING THAT INCLUDES THE BRANCH LINE TO THE RANGE, THE
 TOTAL LENGTH OF THE BRANCH, THE TOTAL DEVELOPED LENGTH
 OF THE SYSTEM FROM THE METER TO THE MOST REMOTE OUTLET,
 AND THE TOTAL BTUH LOAD OF THE SYSTEM - REFER TO
 SECTIONS G2412.3, G2412.4, G2413.1, & G2413.2 FBC RES.
 FUEL GAS.
  
 A) THE SUBMITTED WH SPECS INDICATE 3.5- 10.5 IN. W.C.
 INPUT PRESSURE. SHOW THE DELIVERY PRESSURE AT THE
 METER, THE LOCATION OF THE LOW PRESSURE REGULATOR, THE
 REGULATOR OUTPUT PRESSURE, AND THE REQUIRED PIPE UNIONS
 WITHIN 1 FT. OF EITHER SIDE OF THE REGULATOR- SECTIONS
 G2421.1 & G2421.2.
  
 B) SUBMIT HIGHLIGHTED OR MARKED UP TO SHOW THE SELECTED
 MODEL, THE MAX INLET AND OUTLET SIZE AND PRESSURES, AND
 ORIFICE SIZE. THE SPECS CAN BE DEFERRED AND BE ONSITE
 FOR INSPECTION.
  
 2) PROVIDE A PLAN SHOWING THE INTERIOR OR EXTERIOR
 LOCATION OF THE NEW WATER HEATER. IF INSTALLED ON THE
 EXTERIOR SHOW THE REQUIRED CLEARANCES PER THE
 MANUFACTURER'S SPECIFICATIONS, CLEARANCES FOR SERVICE
 AND MAINTENANCE, AND VENTING CLEARANCES TO OPERABLE
 OPENINGS INTO THE BUILDING- SECTION G2448.1 AND
 G2427.1.
  
 3) IF INSTALLED ON THE INTERIOR PROVIDE COMBUSTION AIR
 AND VENTING PLANS- SECTIONS G2407.1 & G2427.1
  
 4) THE CONTRACTOR OR QUALIFIER WHO PREPARED THE DRAWING
 SHALL PROVIDE HIS/HER SIGNATURE ON IT- SECTION 107.2.1
 WPB, AND FLORIDA STATUTES 471.003(2)(H) & 471.025.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  