Plan Review Notes For Permit 20100046 |
Permit Number |
20100046 |
|
Review Stop |
P |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2021-04-27 10:04:34 | 20100046 529 S FLAGLER DR # 6E | | | | PLUMBING COMMENTS: APPROVED WITH PROVISO | | PROVISO: NO VERTICAL RISE IN FIXTURE DRAIN BETWEEN TRAP | | AND VENT; SEE FBC PL 909.2 | | THE TOTAL FALL IN A FIXTURE DRAIN DUE TO PIPE SLOPE | | SHALL NOT EXCEED THE DIAMETER OF THE FIXTURE DRAIN, NOR | | SHALL THE VENT CONNECTION TO A FIXTURE DRAIN, EXCEPT | | FOR WATER CLOSETS, BE BELOW THE WEIR OF THE TRAP. | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | INSPECTOR'S APPROVAL | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | |
|