Date |
Text |
2020-10-19 10:16:30 | CODES IN EFFECT: |
| FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| 6TH ED, CHAPTER 1. |
| WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL |
| MANUAL REVISED 2017 |
| FBC ACC = FLORIDA ACCESSIBILITY CODE 2017 6TH EDITION |
| FBC EX = FLORIDA EXISTING BUILDING CODE 2017 6TH |
| EDITION |
| FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| FAC= FLORIDA ADMINISTRATIVE CODE |
| FS = FLORIDA STATUTES |
| |
| |
| 1ST REVIEW |
| PLUMBING COMMENTS: DENIED |
| |
| 1.SEE PLAN SHEET A0: PER WPB FBC 107.2.1; A) ADD |
| PLUMBING SHEET B) DELETE REFERENCE TO FLORIDA BUILDING |
| CODE-RESIDENTIAL |
| |
| 2.PER WPB FBC 107.2.1 AND 107.3.5.1.3, PROVIDE A |
| PLUMBING DRAWING TO INCLUDE SANITARY AND WATER PLAN |
| VIEW AND RISER DIAGRAMS SHOWING HOW NEW RELOCATED SINK |
| IS TO CONNECT TO THE EXISTING SERVICES. |
| |
| 3.PLEASE NOTE WHEN DESIGNING THE WASTE AND VENT FOR THE |
| RELOCATED SINK, PER FBC PL 918.3.1, IF AN AIR |
| ADMITTANCE IS INCORPORATED INTO THE DESIGN AND THE |
| HORIZONTAL BRANCH IS LOCATED MORE THAN FOUR BRANCH |
| INTERVALS FROM THE TOP OF THE STACK, THE HORIZONTAL |
| BRANCH SHALL BE PROVIDED WITH A RELIEF VENT THAT SHALL |
| CONNECT TO A VENT STACK OR STACK VENT, OR EXTEND |
| OUTDOORS TO THE OPEN AIR. THE RELIEF VENT SHALL CONNECT |
| TO THE HORIZONTAL BRANCH DRAIN BETWEEN THE STACK AND |
| THE MOST DOWNSTREAM FIXTURE DRAIN CONNECTED TO THE |
| HORIZONTAL BRANCH DRAIN. THE RELIEF VENT SHALL BE SIZED |
| IN ACCORDANCE WITH SECTION 906.2 AND INSTALLED IN |
| ACCORDANCE WITH SECTION 905. THE RELIEF VENT SHALL BE |
| PERMITTED TO SERVE AS THE VENT FOR OTHER FIXTURES. |
| |
| 4.IN ACCORDANCE WITH THE PROVISIONS OF WPB FBC 105.1, A |
| PLUMBING SUB PERMIT IS REQUIRED. |
| |
| 5.PER WPB FBC 107.2.1, PROVIDE NOTE: PER FBC PL |
| 802.1.6, DOMESTIC DISHWASHING MACHINES SHALL DISCHARGE |
| INDIRECTLY THROUGH AN AIR GAP OR AIR BREAK INTO A WASTE |
| RECEPTOR IN ACCORDANCE WITH SECTION 802.2, OR DISCHARGE |
| INTO A WYE BRANCH FITTING ON THE TAILPIECE OF THE |
| KITCHEN SINK OR THE DISHWASHER CONNECTION OF A FOOD |
| WASTE DISPOSER. THE WASTE LINE OF A DOMESTIC |
| DISHWASHING MACHINE DISCHARGING INTO A KITCHEN SINK |
| TAILPIECE OR FOOD WASTE DISPOSER SHALL CONNECT TO A |
| DECK-MOUNTED AIR GAP OR THE WASTE LINE SHALL RISE AND |
| BE SECURELY FASTENED TO THE UNDERSIDE OF THE SINK RIM |
| OR COUNTER. |
| |
| 6.PER WPB FBC 107.2.1, PROVIDE NOTE: PER FBC PL 604.9, |
| A WATER-HAMMER ARRESTOR CONFORMING TO ASSE1010 SHALL BE |
| INSTALLED ON THE HOT WATER SUPPLY TO THE DISHWASHER IN |
| ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. |
| |
| 7. REAL ESTATE RECORDS INDICATE THIS UNIT IS IN A |
| THIRTY-TWO (32) STORY BUILDING. PER WPB FBC 107.2.1, |
| PLEASE CONFIRM OR PROVIDE CORRECT INFORMATION AND |
| PROVIDE THE FOLLOWING INFORMATION. IS THE UNIT ON THE |
| GROUND LEVEL OR AN ELEVATED LEVEL. IS THE FLOOR A RATED |
| FLOOR FOR FIRE? NOTE, IF ANT PLUMBING PIPE IS TO |
| PENETRATE THE FLOOR AND IT IS A FIRE RATED FLOOR THEN A |
| UL ASSEMBLY FOR FIRE SAFEING COMPLYING WITH FBC CHAPTER |
| 7 IS REQUIRED. |
| |
| 8. FS471, DOCUMENTS PREPARED BY AN ENGINEER AND |
| SUBMITTED FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, |
| DATED ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT |
| CONSIDERED AN ORIGINAL.SEE SIGNATURES REVIEW. |
| ALL PLANS TO BE SIGNED AND SEALED BY THE DESIGNER AS |
| REQUIRED BY FAC AND FS OR DIGITALLY SIGNED AND SEALED |
| BY THE DESIGNER IN ACCORDANCE WITH FAC AND FS. |
| |
| |
| END OF COMMENTS. |
| |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| THE PREVIOUSLY REVIEWED SHEETS. |
| |
| |
| JERALD SMITH |
| PLUMBING PLANS EXAMINER |
| CITY OF WEST PALM BEACH |
| EMAIL [email protected] |
| PHONE 561-246-0882 MOBILE |
| |
| 20100046 529 S FLAGLER DR 6E |
| |
| |