Plan Review Notes
Plan Review Notes For Permit 20091355
Permit Number 20091355
Review Stop B
Sequence Number 1
Notes
Date Text
2020-10-06 10:14:22FBC- BUILDING PLAN REVIEW
 W. 2017 P. B. REVISION: 20091355
 W. P. B. PERMIT: 20050806
 ADD: 515 N. FLAGLER DR. SUITE: 650
 CONT: CHANDLER CONSTRUCTION
 TEL: 561-791-6934
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUESDAY OCT. 06TH/2020
 ACTION: DENIED
  
 1) IN THE ORIGINAL ISSUED PERMIT 20050806 SHOWS A
 PARALLEL APPROACH ON SHEET A4.21 DETAIL # 7. THIS SAME
 DETAIL POINTS TO THE SAME PAGE DETAIL # 9 WHICH STATES
 PROVIDE 3 FEET OPEN SPACE UNDERNEATH SINK FOR
 ACCESSIBILITY. THIS SAME DETAIL HAS A CUT SECTION
 THROUGH THE ACCESSIBLE AREA UNDER THE CAF? SINK DETAILS
 # 2 & 5/ PAGE A5.51. PAGE A5.51 DETAIL #2 SHOWS THE
 BASE CABINET AND REQUIRED CLEARANCES FOR A FORWARD
 APPROACH.
 THE SUBMITTED REVISION 20091355 ON SHEET A4.21 STILL
 SHOWS THE CUT SECTION THROUGH THE BASE CABINET PAGE
 A5.51 DETAILS 2 & 5 AND THE REQUIREMENTS CLEAR FLOOR
 SPACE FOR KNEES AND TOES FOR THE FORWARD APPROACH,
 SHOULD THIS DETAIL ALSO BE DELETED SINCE YOU ARE
 LOOKING TO USE A SIDE APPROACH. I BELIEVE YOU ARE
 TRYING TO USE THE EXCEPTION# 1 UNDER 606.2 IN THE 2017
 FBC-ACCESSIBILITY CODE. A PARALLEL APPROACH COMPLYING
 WITH 305 SHALL BE PERMITTED TO A KITCHEN SINK, IN A
 SPACE WHERE A COOK TOP OR CONVENTIONAL RANGE IS NOT
 PROVIDED, AND TO WET BARS.
  
 2) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19, IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  