Plan Review Notes
Plan Review Notes For Permit 20090819
Permit Number 20090819
Review Stop P
Sequence Number 2
Notes
Date Text
2021-02-11 12:18:442ND REVIEW FBC-2017 RES.
 PERMIT- 20090819
 2/11/2021
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
 2ND REVIEW COMMENTS BASED ON NEW ARCHITECTURAL AND
 PLUMBING PLANS.
  
 1) PLUMBING PLAN: PROVIDE SANITARY DRAINAGE AND VENT
 ISOMETRIC DRAWINGS FOR THE NEW AND REMODELED BATHROOMS,
 BAR, KITCHEN AND LAUNDRY ROOMS- SECTION 107.3.5.3 WPB.
  
 2) P PLAN: PROVIDE A CLEANOUT AT THE JUNCTION OF BATH
 #5 DRAIN AND THE SEWER LINE- SECTION P3005.2.3 FBC RES.
  
 3) P PLAN: PROVIDE AN EQUIPMENT SCHEDULE FOR THE NEW
 WATER HEATER AND SUBMIT MANUFACTURER'S SPECIFICATIONS-
 SECTION G2448.1 FBC RES.
  
 4) THE PLUMBING CONTRACTOR OF RECORD WHO PREPARED THE
 PLUMBING DRAWING SHALL SUBMIT A PLUMBING SUB-PERMIT
 APPLICATION- SECTION 105.1 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  