Plan Review Notes For Permit 20090819 |
Permit Number |
20090819 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2020-10-29 09:56:16 | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SHOW COMPLIANCE WITH FBC-R314.3.1 ALTERATIONS, | | REPAIRS AND ADDITIONS. | | WHEN ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A | | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE | | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL | | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS | | LOCATED AS REQUIRED FOR NEW DWELLINGS. | | | | 2) SHOW COMPLIANCE WITH FBC-R315.1 CARBON MONOXIDE | | PROTECTION. | | EVERY SEPARATE BUILDING OR AN ADDITION TO AN EXISTING | | BUILDING FOR WHICH A PERMIT FOR NEW CONSTRUCTION IS | | ISSUED AND HAVING A FOSSIL-FUEL-BURNING HEATER OR | | APPLIANCE, A FIREPLACE, AN ATTACHED GARAGE, OR OTHER | | FEATURE, FIXTURE, OR ELEMENT THAT EMITS CARBON MONOXIDE | | AS A BYPRODUCT OF COMBUSTION SHALL HAVE AN OPERATIONAL | | CARBON MONOXIDE ALARM INSTALLED WITHIN 10 FEET OF EACH | | ROOM USED FOR SLEEPING PURPOSES. | | |
|