Plan Review Notes
Plan Review Notes For Permit 20090700
Permit Number 20090700
Review Stop G
Sequence Number 1
Notes
Date Text
2020-10-06 13:47:421ST REVIEW FBC-2017 RES. FUEL GAS
 PERMIT- 20090700
 10/6/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P0.1: THE TYPES AND SIZES OF PIPING MAKING
 CONNECTIONS FROM THE PE TO THE GWH AND THE RANGE ARE
 NOT SHOWN- SECTION G2413.1 FBC RES.
  
 2) P0.1, REGULATOR DETAIL: PIPE UNIONS ARE REQUIRED
 WITHIN 1 FT. OF EITHER SIDE OF THE REGULATOR- SECTION
 G2421.2(7) FBC RES.
  
 3) P0.1: INDICATE A TRACER WIRE WILL BE INSTALLED
 ADJACENT TO THE UG PE PIPING- SECTION G2415.17.3.
  
 4) SUBMIT SPEC SHEETS FOR THE GENERATOR, WATER HEATER,
 AND RANGE THAT HAVE BEEN MARKED UP OR HIGHLIGHTED TO
 INDICATE THE SELECTED MODELS, BTUH CAPACITIES AND INPUT
 PRESSURES- SECTION G2408.1. PLEASE NOTE THAT
 INSTALLATION OF THE GENERATOR SHALL BE UNDER SEPARATE
 PERMIT AND CURRENTLY THERE IS NO APPLICATION AND PLANS
 SUBMITTED FOR PERMIT ISSUANCE- SECTION 105.1 & 107.2.1
 WPB.
  
 5) SUBMIT MARKED UP OR HIGHLIGHTED REGULATOR SPECS
 SHOWING THE SELECTED MODELS TO BE INSTALLED, INLET AND
 OUTLET PIPE SIZES AND PRESSURES, SPRING SELECTIONS, AND
 ORIFICE SIZES- SECTIONS G2421.1 & G2421.2 FBC RES.
  
 6) SHEET PS1.1: SHOW THE GENERATOR CLEARANCE DISTANCES
 TO THE BUILDINGS, ADJACENT PROPERTY LINES, AND TO
 MECHANICAL AIR INTAKES AND OPERABLE OPENINGS INTO THE
 BUILDING- SECTION 4.1.4 NFPA 37, AND SECTION R303.5.1
 FBC RES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved