2020-10-29 11:19:41 | 1ST REVIEW FBC-2017 RES. FUEL GAS |
| PERMIT- 20090465 |
| 10/29/2020 |
| |
| CODES IN EFFECT: |
| FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| EDITION 2017 |
| FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| 2017 |
| FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| EDITION 2017 |
| |
| PLAN REVIEW RESULTS: DENIED. |
| |
| 1) PROVIDE A PERMIT APPLICATION FOR THE PROPOSED GAS |
| PIPING INSTALLATION- SECTION 105.1 WPB. |
| |
| 2) GAS RISER DRAWING: |
| A) SHOW ALL PIPE SIZES INCLUDING THE MAIN PIPE FROM THE |
| METER TO THE TEE, THE MAIN RUN, AND THE BRANCHES TO THE |
| APPLIANCES- SECTION G2413.1 FBC RES. |
| B) SHOW THE LOCATIONS OF THE LOW PRESSURE REGULATORS |
| AND THE OUTPUT PRESSURES AT EACH APPLIANCE- SECTION |
| G2421.1. SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE |
| REGULATORS MARKED UP OR HIGHLIGHTED TO SHOW THE |
| SELECTED MODEL, INPUT AND OUTPUT PRESSURES AND PIPE |
| SIZES, AND ORIFICE SIZES. |
| C) SHOW THE REQUIRED PIPE UNIONS FOR RIGID PIPING |
| WITHIN 1 FT. OF EITHER SIDE THE REGULATORS- SECTION |
| G2421.2(7). |
| |
| 3) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE |
| GAS-FIRED APPLIANCES OR PLACE A NOTE THAT THE SPECS |
| WILL BE ONSITE AT TIME OF INSPECTION- SECTION 107.2.1 |
| WPB. THE SPECS SHALL BE MARKED UP OR HIGHLIGHTED TO |
| INDICATE THE BTUH LOADS AND INPUT PRESSURES. |
| |
| 4) THE CONTRACTOR OR QUALIFIER WHO PREPARED THE |
| DRAWINGS SHALL PROVIDE HIS COMPLETE SIGNATURE- FIRST |
| AND LAST NAME- ON BOTH PLANS- SECTION 107.2.1 WPB, AND |
| FLORIDA STATUTES 471.003(2)(H) & 471.025. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |