| PLAN REVIEW RESULTS: DENIED. |
| |
| 1) SHEET P1 WATER ISOMETRIC AND WATER PLAN: |
| |
| A) INSTA-HOT WATER HEATERS LABELED ON PLAN NOT SHOWN ON |
| THE ISOMETRIC- SECTION 107.2.1 WPB. |
| |
| B) LOCATION OF WATER HEATER EXPANSION TANK SHOWN ON HOT |
| WATER PIPE IS NOT IN COMPLIANCE WITH SECTION 607.3 FBC |
| P. CORRECT LOCATION ON THE COLD WATER INLET PIPE IS |
| SHOWN IN THE WATER HEATER DETAIL. |
| |
| C) TWO BATCH BREWERS ARE SHOWN BUT THE ISOMETRIC AND |
| PLAN SHOW ONLY ONE FILTERED WATER LINE CONNECTION- |
| SECTION 107.2.1 WPB. |
| |
| D) WATER SUPPLY CONNECTION TO ESPRESSO MACHINE AND |
| RINSER SHOWN ON THE ISOMETRIC BUT ON THE PLAN- SECTION |
| 107.2.1 WPB. |
| |
| E) PROVIDE A BACKFLOW DEVICE FOR THE WATER SUPPLY TO |
| THE RINSER AND INDICATE THE MAKE AND MODEL OF ALL |
| BACKFLOW DEVICES SHOWN ON THE RISER- SECTION 608.3 FBC |
| P. |
| |
| F) PROVIDE WATER HAMMER ARRESTORS FOR SUPPLY LINES TO |
| THE FILTRATION SYSTEM, BATCH BREWERS, EXPRESSO MACHINE |
| ETC.- SECTION 604.9 FBC P. |
| |
| G) THERE IS A NOTE INDICATING WATER SUPPLY TO THE |
| KETTLES HOWEVER THE WATER SUPPLY LINES ARE NOT SHOWN- |
| SECTION 107.2.1 WPB. |
| |
| H) INDICATE HOW TEMPERED WATER WILL BE PROVIDED TO THE |
| LAVATORY- SEE SECTIONS 416.5 AND 607.1.2 FBC P. |
| |
| I) IT APPEARS A 3/4 IN. HOT WATER PIPE IS SUPPLYING THE |
| NEW LAVATORY. PLEASE SEE SECTION C404.5.1 AND TABLE |
| C404.5.1 FBC EC- A 3/4 IN. PIPE IS LIMITED TO A MAXIMUM |
| LENGTH OF 0.5 FT. FROM THE NEAREST HOT WATER SOURCE. |
| |
| 2) SHEET P1.0: THE SANITARY ISOMETRIC APPEARS TO SHOW A |
| SINGLE DRAIN PIPE FROM THE 3-COMPARTMENT SINK |
| DISCHARGING INTO THE FLOOR SINK. PLEASE SEE SECTION |
| 802.1.1 FBC P AND PROVIDE A DETAIL SHOWING EACH WELL OF |
| THE SINK DISCHARGING INDEPENDENTLY INTO THE FLOOR SINK. |
| 3) P1.0: PLEASE ADD SLAB CUTTING FOR UNDERGROUND DRAINS |
| AND WATER SUPPLY PIPING IN THE PLUMBING DEMOLITION |
| NOTES- SECTION 107.2.1 WPB. REFERENCE IS MADE TO A SLAB |
| REPAIR DETAIL ON SHEET A4.0 HOWEVER THERE IS NO SHEET |
| A4.0 IN THE SET- SECTION 107.2.1 WPB. |
| |
| 4) P1.0 PLUMBING SPECIFICATIONS: PROVIDE DWV AND WATER |
| SUPPLY AND FILTERED WATER SUPPLY PIPING MATERIAL |
| SPECIFICATIONS, AND THE TYPE AND SIZE OF HOT WATER PIPE |
| INSULATION- SECTIONS303.1 & 303.2 FBC P, AND TABLE |
| C403.2.10 FBC EC. |
| |
| 5) P1.0: INDICATE HOW UNDER SLAB WATER PIPING WILL |
| PROTECTED FROM CORROSION- SECTION 305.1 FBC P. |
| |
| 6) P1.0- MISSING ACCESSIBILITY DETAILS- FBC- ACC. |
| A) WATER CLOSET AND LAVATORY CLEAR FLOOR SPACE |
| DIMENSIONS- SECTIONS 604.3 & 606.2. |
| B) GRAB LOCATIONS AND LENGTHS NOT SHOWN CORRECTLY |
| ACCORDING TO SECTION 604.5 & FIGURES 604.5.1 & 604.5.2 |
| C) LAVATORY KNEE AND TOE CLEARANCES- SECTION 606.2. |
| |
| 7) 2ND REQUEST FOR PLUMBING FIXTURES CALCULATIONS IN |
| ACCORDANCE WITH TABLE 403.1 FBC P. PROVIDE A SCHEDULE |
| THAT INDICATES THE REQUIRED AND PROVIDED NUMBER OF |
| FIXTURES. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |