Plan Review Notes
Plan Review Notes For Permit 20090239
Permit Number 20090239
Review Stop NFIP
Sequence Number 3
Notes
Date Text
2020-12-17 09:42:47PLAN REVIEW / NFIP
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER BUILDING - PX3169
 PLANS EXAMINER 1&2 FAMILY - SFP306
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 CODES IN EFFECT:
 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 CITY ORDINANCE NO. 4658-16
  
 3RD REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED
 SATISFACTORILY ARE MARKED AS CORRECTED.
 PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED
 SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN
 PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER
 PREVIOUS COMMENTS.
  
  
 RE: CONSTRUCTION DRAWING ELEVATION CERTIFICATE (EC)
  
 1. REF. LINE A5 OF EC. LATITUDE IS STATED AS 39 33 81
 N. GOOGLE MAPS/GOOGLE EARTH SHOWS THE LATITUDE FOR 6175
 S FLAGLER AS 26 39 24 N. PLEASE CORRECT LATITUDE.
 CORRECTED
  
  
 2. ORIGINAL SIGNATURE OF SURVEYOR IS REQUIRED. (NOT
 CORRECTED)
  
 A SCAN OF A WET SEAL AND SIGNATURE OR DIGITAL SIGNATURE
 IS NOT CONSIDERED A DIGITAL SIGNATURE.
  
 EITHER UPLOAD A VALID DIGITALLY SIGNED DOCUMENT OR DROP
 OFF (OR MAIL) ONE PAPER ORIGINAL WITH AN ORIGINAL WET
 SEAL AND SIGNATURE TO:
  
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS ST
 WEST PALM BEACH, FL 33401
  
 NEW COMMENTS:
  
 3. . FLOOD VENTS SHALL BE INSTALLED ON ADJACENT WALLS
 OF ENCLOSED AREAS. SUBMIT NEW PLAN PAGES THAT SHOW THE
 LOCATION OF THE VENTS.
 R322.2.2.1INSTALLATION OF OPENINGS. T
 THE WALLS OF ENCLOSED AREAS SHALL HAVE OPENINGS
 INSTALLED SUCH THAT:
 1. 1.THERE SHALL BE NOT LESS THAN TWO OPENINGS ON
 DIFFERENT SIDES OF EACH ENCLOSED AREA; IF A BUILDING
 HAS MORE THAN ONE ENCLOSED AREA BELOW THE DESIGN FLOOD
 ELEVATION, EACH AREA SHALL HAVE OPENINGS.
 2. 2.THE BOTTOM OF EACH OPENING SHALL BE NOT MORE THAN
 1 FOOT (305 MM) ABOVE THE HIGHER OF THE FINAL INTERIOR
 GRADE OR FLOOR AND THE FINISHED EXTERIOR GRADE
 IMMEDIATELY UNDER EACH OPENING.
 3. 3.OPENINGS SHALL BE PERMITTED TO BE INSTALLED IN
 DOORS AND WINDOWS; DOORS AND WINDOWS WITHOUT INSTALLED
 OPENINGS DO NOT MEET THE REQUIREMENTS OF THIS SECTION.
 ALSO SEE SEC. 4.1 OF THE ICC-ES REPORT FOR VENT
 LOCATION.
 ALSO SEE FEMA TECHNICAL BULLETIN #1 - FLOOD OPENINGS IN
 WALLS.
  
 NOTICE: PROVIDE BUILDING UNDER CONSTRUCTION ELEVATION
 CERTIFICATE TO CITY INSPECTOR AT PLACEMENT OF 1ST
 FLOOR.
 PROVIDE FINISHED CONSTRUCTION ELEVATION CERTIFICATE
 PRIOR TO C/O.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
  
  
  
  
  