2020-12-17 09:04:43 | PLAN REVIEW / BUILDING |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| PLANS EXAMINER BUILDING - PX3169 |
| PLANS EXAMINER 1&2 FAMILY - SFP306 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| CODES IN EFFECT: |
| 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| NEC 2014 |
| |
| 3RD REVIEW |
| |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| PROVISO: GENERATOR SHALL BE BY SEPERATE PERMIT. |
| |
| PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED |
| SATISFACTORILY ARE MARKED AS CORRECTED. |
| PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED |
| SATISFACTORILY MAY HAVE ADDITIONAL COMMENTS IN |
| PARENTHESES. ANY NEW COMMENT WILL BE LISTED AFTER |
| PREVIOUS COMMENTS. |
| |
| 1. ALL PLAN SHEETS HAVE AN INCORRECT ADDRESS. (101 |
| SANTA LUCIA DRIVE). THE CORRECT ADDRESS IS 6175 S |
| FLAGLER DRIVE. PLEASE CORRECT AND RE-SUBMIT. (NOT |
| CORRECTED) |
| |
| 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS |
| SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH |
| 107.2.5. |
| |
| 2. PROVIDE ICC-ES REPORT AND PRODUCT APPROVALS FOR |
| SMART VENTS. (ICC-ES REPORT RCV'D. PROVIDE INSTALLATION |
| INSTRUCTIONS FOR SMART VENT MODEL 1540-511). |
| |
| FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE |
| PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| |
| NEW COMMENTS: |
| |
| 3. REFERENCE YOUR PERMIT REVIEW RESPONSE LTR DATED |
| 12/11/2020: ALTHOUGH MULTIPLE DOCUMENTS SUCH AS PRODUCT |
| APPROVALS, NOC, SOILS REPORT, ETC. MAY BE UPLOADED AS |
| ONE PDF, THE ELEVATION CERTIFICATE MUST BE UPLOADED |
| SEPERATELY. WE HAVE TO SUBMIT THESE TO FEMA AND NEED A |
| CLEAN EC WITHOUT ANY ATTACHMENTS. |
| ALSO, PLEASE FOLLOW THE FILE NAMING GUIDELINES ON THE |
| QUICK START GUIDE AND PROVIDE THE NAME OF THE DOCUMENTS |
| INCLUDED IN THE FILE. |
| IT'S PREFERABLE BUT NOT REQUIRED FOR EACH DOCUMENT TO |
| BE UPLOADED SEPERATELY WITH IT'S APPROPRIATE NAME. THIS |
| HELPS THE REVIEW PROCESS TREMENDOUSLY. |
| |
| 4. I DO NOT SEE A NEW SURVEY IN THE RESPONSE LTR DOC. |
| THE SURVEY SHOULD ALSO BE UPLOADED AS A SEPERATE FILE. |
| |
| 5. FLOOD VENTS SHALL BE INSTALLED ON ADJACENT WALLS. |
| SUBMIT NEW PLAN PAGES THAT SHOW THE LOCATION OF THE |
| VENTS. |
| R322.2.2.1INSTALLATION OF OPENINGS. |
| THE WALLS OF ENCLOSED AREAS SHALL HAVE OPENINGS |
| INSTALLED SUCH THAT: |
| 1. 1.THERE SHALL BE NOT LESS THAN TWO OPENINGS ON |
| DIFFERENT SIDES OF EACH ENCLOSED AREA; IF A BUILDING |
| HAS MORE THAN ONE ENCLOSED AREA BELOW THE DESIGN FLOOD |
| ELEVATION, EACH AREA SHALL HAVE OPENINGS. |
| 2. 2.THE BOTTOM OF EACH OPENING SHALL BE NOT MORE THAN |
| 1 FOOT (305 MM) ABOVE THE HIGHER OF THE FINAL INTERIOR |
| GRADE OR FLOOR AND THE FINISHED EXTERIOR GRADE |
| IMMEDIATELY UNDER EACH OPENING. |
| 3. 3.OPENINGS SHALL BE PERMITTED TO BE INSTALLED IN |
| DOORS AND WINDOWS; DOORS AND WINDOWS WITHOUT INSTALLED |
| OPENINGS DO NOT MEET THE REQUIREMENTS OF THIS SECTION. |
| ALSO SEE SEC. 4.1 OF THE ICC-ES REPORT FOR VENT |
| LOCATION. |
| ALSO SEE FEMA TECHNICAL BULLETIN #1 - FLOOD OPENINGS IN |
| WALLS. |
| |
| |
| WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| |
| |
| |
| |
| |