2020-11-20 11:49:46 | 1ST REVIEW FBC-2017 MECHANICAL |
| PERMIT-20090239 |
| |
| CODES IN EFFECT: |
| |
| FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| 2017 |
| FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| 2017 |
| FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH |
| EDITION 2017 |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| EDITION 2017 |
| |
| PLAN REVIEW RESULTS: DENIED. |
| |
| 1) PLEASE PROVIDE BATH EXHAUST FAN AND EXHAUST |
| TERMINATION FOR THE BATHROOM ON THE MAIN FLOOR IN THE |
| JR. MASTER BEDROOM. FBC RES TABLE M1507.4, FBC RES |
| M1506.3 |
| |
| 2) PLEASE SHOW BATH EXHAUST FAN AND EXHAUST TERMINATION |
| FOR THE POWDER ROOM ON THE MAIN FLOOR. FBC RES TABLE |
| M1507.4, FBC RES M1506.3 |
| |
| 3) PLEASE PROVIDE BATH EXHAUST FAN AND EXHAUST |
| TERMINATION FOR THE TUB AREA OF HER BATH ROOM. FBC RES |
| TABLE M1507.4, FBC RES M1506.3 |
| |
| 4) PLEASE SHOW HOOD DUCT TERMINATION LOCATION. FBC RES |
| M1503.1 |
| |
| 5) PLEASE SHOW THE AHU LOCATION FOR BEDROOMS 2 AND 3. |
| FBC 107.2 |
| |
| 6) PLEASE SHOW THE MAKE UP AIR INTAKE LOCATION ON THE |
| DRAWING. FBC 107.2 |
| |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT |
| CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD |
| SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER |
| SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN |
| THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS |
| PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS |
| PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR |
| UPDATED. |
| |
| MICHAEL EDWARDS |
| MECHANICAL EXAMINER |
| 401 CLEMATIS STREET |
| WEST PALM BEACH FL. 33401 |
| 561-805-6728 |
| [email protected] |
| |