Plan Review Notes
Plan Review Notes For Permit 20090229
Permit Number 20090229
Review Stop P
Sequence Number 4
Notes
Date Text
2020-10-01 12:49:17 
 3RD REVIEW FBC-2017 RES. PLUMBING
 PERMIT- 20090229
 10/1/2020
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE SIXTH
 EDITION 2017
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SURVEY DRAWING: SHOW THE LOCATION OF THE REQUIRED
 CLEANOUT AT THE BUILDING DRAIN AND SEWER JUNCTION-
 SECTION P3005.2.3 FBC RES.
  
 2) PROVIDE A SLAB REPAIR DETAIL PER SECTION 107.21 WPB,
 AND VERIFY THE DISTURBED SOIL AT THE SLAB CUT LOCATIONS
 WILL BE TERMITE TREATED IN ACCORDANCE WITH SECTIONS
 R318.1.2, 318.1.3 & 318.1.4 FBC RES.
  
 3) THE SIGNATURE OF THE PLUMBING CONTRACTOR OF RECORD
 SHALL BE ON THE PLUMBING PLAN AND THE MARKED-UP SURVEY
 DRAWING PER SECTION- 107.2.1 WPB, AND FL. STATUTES
 471.003(2)(H) & 471.025.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  