2020-10-21 13:11:18NEW SFR
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2017 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107
 1) ONE BATHROOM NEEDS TO HAVE A 29" DOOR OPENING
 CLEARANCE AT TOILET ROOM. FBC R320.1.1 - PLEASE SHOW
 HOW THE 2'6" DOOR WILL ALLOW A CLEAR WIDTH OF 29" - FBC
 ACCESSIBILITY 404.2.3 CLEAR OPENINGS OF DOORWAYS WITH
 SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF
 THE DOOR AND THE STOP, WITH THE DOOR OPEN 90 DEGREES.
  
  
  