2020-11-03 09:42:34 
 1) PLEASE SHOW THE BUILDING USE (OCCUPANCY
 CLASSIFICATION PER FBC CHAPTER 3.
 2) PLEASE SHOW THE WALL AND FLOOR FINISHES TO COMPLY
 WITH FBC 1210.2.2. EPOXY PAINT ON DRYWALL DOES NOT MEET
 THE INTENT OF THE CODE.
 3) PLEASE SHOW THE BOTTOM OF THE MIRROR'S REFLECTIVE
 SURFACE TO THE FINISHED FLOOR TO COMPLY WITH FBC
 ACCESSIBILITY 603.3 MIRRORS.
 MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL
 BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING
 SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
 4) THE 24" AND 12" ON THE GRAB BAR BEHIND THE TOILET
 NEED TO BE SHOWN FROM THE CENTER LINE OF THE WATER
 CLOSET SEE FBC ACCESSIBILITY FIGURE 604.5.2
 5) TOILET PAPER DISPENSER - THE 7" TO 9" NEEDS TO BE
 SHOWN TO THE CENTER OF THE DISPENSER SEE FBC
 ACCESSIBILITY FIGURE 604.7
 6) THE LOCATION OF THE GRAB BAR ADJACENT TO THE TOILET
 SHALL COMPLY WITH FBC-ACCESS. SEC.604.5.1 & FIGURE
 604.5.1.
 7) THE SIDE ELEVATION STILL SHOWS THE GRAB BAR MEASURED
 TO THE CENTERLINE OF THE BAR. THE BAR SHALL BEE MEASURE
 TO THE TOP OF THE GRIPPING SURFACE. FBS- ACCESS.
 609..4.
 8) SHOW THE REQUIRED CLEAR FLOOR SPACE DIMENSIONS FOR
 THE TOILET AND LAVATORY IN THE TOILET ROOM PER
 FBC-ACCESS. SECS. 604.3.1 AND FIGURE 604.3.1 AND 606..2
 AND SECS.305 & 306.
  