Plan Review Notes
Plan Review Notes For Permit 20080894
Permit Number 20080894
Review Stop Z
Sequence Number 1
Notes
Date Text
2020-10-02 16:40:50FAILED
  
 ARCADE IDENTITY SIGN
  
 1) THE ROSEMARY SQUARE TENANT SIGN CRITERIA LIMITS THE
 SIGN COPY TO TRADE NAMES ONLY. THE OF THE LOGO IS ONLY
 PERMITTED AS A WAIVER I. A WAIVER I REQUIRES WRITTEN
 APPROVAL FROM CITYPLACE RETAIL.
  
 2) THE ROSEMARY SQUARE SIGN CRITERIA MEASURES SIGNAGE
 ALLOWANCE AS FOLLOWS - ONE SQUARE FOOT OF SIGNAGE FOR
 EACH ONE LINEAR FOOT OF STORE FRONTAGE. PLEASE PROVIDE
 THE LINEAR FEET OF STORE FRONTAGE.
  
 3) HE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE THAT
 ARCADE IDENTITY SIGNS BE CENTERED WITHIN THE ARCADE
 ARCHWAY AND THAT IT MUST FIT WITHIN THE ARCADE COLUMNS.
 THE OUTSIDE EDGES OF THE SIGN OVERLAPPING THE COLUMNS
 IS NOT PERMITTED.
  
 4) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE THE
 STUD MOUNTS TO BE SERIES 316 STAINLESS STEEL ANCHOR
 BOLTS. PROVIDE VERIFICATION OF THIS REQUIREMENT ON THE
 PLANS. THIS IS NOT SPECIFIED ON THE PLANS.
  
 5) THE ROSEMARY SQUARE TENANT SIGN CRITERIA ONLY PERMIT
 WHITE, NOT CLEAR, ACRYLIC FOR PUSH THROUGH
 APPLICATIONS. THE USE OF ALTERNATIVE MATERIALS IS ONLY
 PERMITTED AS A WAIVER I. A WAIVER I REQUIRES WRITTEN
 APPROVAL FROM CITYPLACE RETAIL.
  
 6) THE ROSEMARY SQUARE TENANT SIGN CRITERIA SIGNS
 PROHIBIT SIGNS MADE WITH LEXAN. THE USE OF ALTERNATIVE
 MATERIALS IS ONLY PERMITTED AS A WAIVER I. A WAIVER I
 REQUIRES WRITTEN APPROVAL FROM CITYPLACE RETAIL.
  
 7) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRES
 THAT ALL CONDUIT, CROSSOVERS, WIRING NECESSARY FOR THE
 SIGN'S ELECTRICAL CONNECTION TO BE CONCEALED AND NOT
 VISIBLE TO THE PUBLIC. THE PLANS STATE THAT ALL WIRING
 WILL BE CONCEALED. THE CONDUIT THAT THE WIRING IS IN
 ALSO NEEDS TO BE CONCEALED. PROVIDE HOW THIS WILL
 OCCUR.
  
 PERMITTED SIGNAGE: ?? SF
 PROPOSED SIGNAGE: 11.7 SF
  
 WINDOW GRAPHICS
  
 1) HE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT
 WINDOW GRAPHICS THAT COVER UP TO 20% OF THE GLAZED AREA
 OF THE APPLICABLE STOREFRONT. PROVIDE VERIFICATION THAT
 THE GRAPHICS COVER NO MORE THAN 20%.
  
 2) PROVIDE THE MATERIAL OF THE WINDOW GRAPHICS AND
 VERIFICATION THAT THEY ARE APPLIED ON THE INTERIOR SIDE
 OF THE GLASS (UNLESS IT IS PAINTED, THEN IT MAY BE
 APPLIED ON THE EXTERIOR SIDE OF THE GLASS).
  