Plan Review Notes For Permit 20080500 |
Permit Number |
20080500 |
|
Review Stop |
B |
Sequence Number |
3 |
|
Notes |
Date |
Text |
2020-11-12 13:02:16 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS TUESDAY & THURSDAY 7:00 AM TO 3:00 PM | | ALTERNATE: CONTACT PETER VALENTI (561) 805-6673 | | [email protected] | | | | 1ST REVIEW: FBC 2017 6TH EDITION | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected] AND REQUEST | | THAT IT BE CONVERTED TO PROJECTDOX. | | | | 1 FBC B 107.2.1. ON THE SCHEDULE FOR INSTALLATION OF | | PROTECTIVE DEVICES OR ASSEMBLIES: PLEASE CORRECT COLUMN | | HEADING ?ANCHOR SPACING?; ??ELCO ULTRACON WITH 2.5? | | MIN. EDGE DISTANCE, C-3 CONNECTION TYPE INTO HOLLOW | | (CONCRETE) BLOCK IS NOT AN ACCEPTABLE ANCHOR CONDITION; | | PLEASE CORRECT FOR ITEMS 1-6. VERIFY ALL ANCHOR | | SPACINGS AS REQUIRED FOR CONNECTION TYPES, DESIGN | | PRESSURES, STRUCTURE TYPE AND ANCHOR TYPE USED. | | |
|