Date |
Text |
2020-09-23 13:14:48 | BUILDING REVIEW COMMENTS |
| CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| |
| NOTE: SEC. 801.3 FBC-EXISTING BUILDING. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE. |
| |
| 1- PLANS SUBMITTED ARE SIGNED BY A LICENSED ENGINEER. |
| BASED ON THE SCOPE OF WORK SHOWN ON PLANS, IT LOOKS |
| LIKE THE SCOPE OF WORK FALLS UNDER THE SCOPE OF |
| ARCHITECTURE NO ENGINEERING. THE ARCHITECTURAL SCOPE OF |
| WORK SHOWN IS NOT INCIDENTAL TO ENGINEERING. PLANS |
| SHOWING THE PROPOSED USE OF THE SPACE NEEDS TO BE DONE |
| BY A LICENSED ARCHITECT. CHAPTER 481 FLORIDA STATUES |
| AND 61G1 FLORIDA ADMINISTRATIVE CODE. |
| (NOTE: SEE DEFINITIONS BELOW FOR ARCHITECTURE AND |
| ENGINEERING DEFINITIONS). |
| |
| 2- PROVIDE COMPLETE LIFESAFETY PLAN SHOWING COMPLIANCE |
| WITH THE EGRESS REQUIREMENTS. PROVIDE THE OCCUPANT LOAD |
| AND EGRESS CAPABILITIES. SEC. 107.3.5.1 CITY |
| AMENDMENTS. |
| |
| 3- TYPE OF CONSTRUCTION IS INCORRECT. THIS BUILDING IS |
| NOT TYPE 5B CONSTRUCTION. REVISE AS REQUIRED. SEC. |
| 602.1 FBC-BUILDING. |
| |
| 4- PROVIDE COMPLETE INFORMATION FOR THE EGRESS DOORS. |
| SEC. 1010.1 FBC-BUILDING |
| FIRE RATING, SWING IN THE DIRECTION OF TRAVEL, |
| HARDWARE, LOCKING MECHANISM, ETC. |
| |
| |
| WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE |
| ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF |
| THE REVISION MADE, IDENTIFYING THE SHEET OR |
| SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL |
| HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR |
| ANTICIPATED COOPERATION. |
| |
| PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| QUESTIONS REGARDING THESE COMMENTS, |
| JULIO GOMEZ |
| COMMERCIAL COMBINATION PLANS EXAMINER |
| DEVELOPMENT SERVICES DEPARTMENT |
| BUILDING DIVISION |
| (561)805-6712 |
| [email protected] |
| |
| |
| ARCHITECTURE: |
| 481.203. DEFINITIONS. AS USED IN THIS PART: |
| (6) ARCHITECTURE MEANS THE RENDERING OR OFFERING TO |
| RENDER SERVICES IN CONNECTION WITH THE DESIGN AND |
| CONSTRUCTION OF A STRUCTURE OR GROUP OF STRUCTURES |
| WHICH HAVE AS THEIR PRINCIPAL PURPOSE HUMAN HABITATION |
| OR USE, AND THE UTILIZATION OF SPACE WITHIN AND |
| SURROUNDING SUCH STRUCTURES. THESE SERVICES INCLUDE |
| PLANNING, PROVIDING PRELIMINARY STUDY DESIGNS, DRAWINGS |
| AND SPECIFICATIONS, JOB-SITE INSPECTION, AND |
| ADMINISTRATION OF CONSTRUCTION CONTRACTS. |
| |
| ENGINEERING |
| 471.005. DEFINITIONS. AS USED IN THIS CHAPTER, THE |
| TERM: |
| (7)ENGINEERING? INCLUDES THE TERM PROFESSIONAL |
| ENGINEERING AND MEANS ANY SERVICE OR CREATIVE WORK, THE |
| ADEQUATE PERFORMANCE OF WHICH REQUIRES ENGINEERING |
| EDUCATION, TRAINING, AND EXPERIENCE IN THE APPLICATION |
| OF SPECIAL KNOWLEDGE OF THE MATHEMATICAL, PHYSICAL, AND |
| ENGINEERING SCIENCES TO SUCH SERVICES OR CREATIVE WORK |
| AS CONSULTATION, INVESTIGATION, EVALUATION, PLANNING, |
| AND DESIGN OF ENGINEERING WORKS AND SYSTEMS, PLANNING |
| THE USE OF LAND AND WATER, TEACHING OF THE PRINCIPLES |
| AND METHODS OF ENGINEERING DESIGN, ENGINEERING SURVEYS, |
| AND THE INSPECTION OF CONSTRUCTION FOR THE PURPOSE OF |
| DETERMINING IN GENERAL IF THE WORK IS PROCEEDING IN |
| COMPLIANCE WITH DRAWINGS AND SPECIFICATIONS, ANY OF |
| WHICH EMBRACES SUCH SERVICES OR WORK, EITHER PUBLIC OR |
| PRIVATE, IN CONNECTION WITH ANY UTILITIES, STRUCTURES, |
| BUILDINGS, MACHINES, EQUIPMENT, PROCESSES, WORK |
| SYSTEMS, PROJECTS, AND INDUSTRIAL OR CONSUMER PRODUCTS |
| OR EQUIPMENT OF A MECHANICAL, ELECTRICAL, HYDRAULIC, |
| PNEUMATIC, OR THERMAL NATURE, INSOFAR AS THEY INVOLVE |
| SAFEGUARDING LIFE, HEALTH, OR PROPERTY; AND INCLUDES |
| SUCH OTHER PROFESSIONAL SERVICES AS MAY BE NECESSARY TO |
| THE PLANNING, PROGRESS, AND COMPLETION OF ANY |
| ENGINEERING SERVICES. A PERSON WHO PRACTICES ANY BRANCH |
| OF ENGINEERING; WHO, BY VERBAL CLAIM, SIGN, |
| ADVERTISEMENT, LETTERHEAD, OR CARD, OR IN ANY OTHER |
| WAY, REPRESENTS HIMSELF OR HERSELF TO BE AN ENGINEER |
| OR, THROUGH THE USE OF SOME OTHER TITLE, IMPLIES THAT |
| HE OR SHE IS AN ENGINEER OR THAT HE OR SHE IS LICENSED |
| UNDER THIS CHAPTER; OR WHO HOLDS HIMSELF OR HERSELF OUT |
| AS ABLE TO PERFORM, OR DOES PERFORM, ANY ENGINEERING |
| SERVICE OR WORK OR ANY OTHER SERVICE DESIGNATED BY THE |
| PRACTITIONER WHICH IS RECOGNIZED AS ENGINEERING SHALL |
| BE CONSTRUED TO PRACTICE OR OFFER TO PRACTICE |
| ENGINEERING WITHIN THE MEANING AND INTENT OF THIS |
| CHAPTER. |
| |
| ENGINEERS |
| SEC. 471.003 |
| |
| (3) NOTWITHSTANDING THE PROVISIONS OF THIS CHAPTER OR |
| OF ANY OTHER LAW, NO LICENSED ENGINEER WHOSE PRINCIPAL |
| PRACTICE IS CIVIL OR STRUCTURAL ENGINEERING, OR |
| EMPLOYEE OR SUBORDINATE UNDER THE RESPONSIBLE |
| SUPERVISION OR CONTROL OF THE ENGINEER, IS PRECLUDED |
| FROM PERFORMING ARCHITECTURAL SERVICES WHICH ARE PURELY |
| INCIDENTAL TO HER OR HIS ENGINEERING PRACTICE, NOR IS |
| ANY LICENSED ARCHITECT, OR EMPLOYEE OR SUBORDINATE |
| UNDER THE RESPONSIBLE SUPERVISION OR CONTROL OF THE |
| ARCHITECT, PRECLUDED FROM PERFORMING ENGINEERING |
| SERVICES WHICH ARE PURELY INCIDENTAL TO HER OR HIS |
| ARCHITECTURAL PRACTICE. HOWEVER, NO ENGINEER SHALL |
| PRACTICE ARCHITECTURE OR USE THE DESIGNATION |
| ?ARCHITECT? OR ANY TERM DERIVED THEREFROM, AND NO |
| ARCHITECT SHALL PRACTICE ENGINEERING OR USE THE |
| DESIGNATION ?ENGINEER? OR ANY TERM DERIVED THEREFROM. |
| |