Plan Review Notes For Permit 20071169 |
Permit Number |
20071169 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2020-08-07 08:11:51 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SIXTH EDITION (2017) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT A ROOF PLAN. SPECIFY THE AREA THAT WILL BE | | RE-ROOFED, THE DIMENSIONS OF THE ROOF AREAS, THE MEAN | | ROOF HEIGHT, LOCATIONS OF ROOF DRAINS AND SCUPPERS IF | | ANY. FBC 107.2.1 | | | | 2) HI LIGHT OR CIRCLE THE ITEMS IN THE PRODUCT | | APPROVALS THAT APPLY TO THIS PROJECT. IF THE DESIGN | | PRESSURES ON THE PRODUCT APPROVAL FOR THE PROJECT ARE | | LESS THAN -95.7 PSF FOR A 15' MEAN ROOF HEIGHT, THEN | | SIGNED AND SEALED ENHANCED FASTENING CALCULATIONS WILL | | BE REQUIRED. FBC 107.2.1 |
|