2020-07-27 15:43:04WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20070736
 ADD: 501 S. FLAGLER DR. 5TH FLOOR COMMON AREAS/ ADA
 RESTROOMS
 CONT: ANDERSON & MOORE CONSTRUCTION
 TEL: 561-348-4805
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: MON. JULY 27TH/ 2020
 ACTION: DENIED
  
 1) CLARIFICATION IN PLANS. IN THE TITLE BLOCK THE PLANS
 STATE THEY ARE FOR FLOORS 4 & 5. THE INDEX STATES THE
 RESTROOMS ARE TO BE A SLTERNATE LAYOUT (ACCESSIBLE).
 PLEASE CLARIFY IN THE TITLE BLOCK OR IN THE BODY OF THE
 PLANS WHICH FLOOR IS TOHAVE THE ACCESSIBLE STALLS.
 107.2.1.2 ADDITIONAL INFORMATION IS REQUIRED,
 CLARIFICATION IN PLANS. THANK YOU.
  
  
 2) SHEET A1.1.4 DETAILS FOR ACCESSIBLE RESTROOMS SHOW
 THE GRAB BARS FOR THE WATER CLOSET MEASURED AT 36
 INCHES FROM FLOOR TO CENTER LINE OF THE GRAB BAR. 2017
 FBC-ACCESSIBILITY CODE SECTION 609.4 POSITION OF GRAB
 BARS. GRAB BARS SHALL BE INSTALLED IN A HORIZONTAL
 POSITION, 33 INCHES MINIMUM AND 36 INCHES MAXIMUM ABOVE
 THE FINISH FLOOR MEASURED TO THE TOP OF THE GRIPPING
 SURFACE, NOT CENTERLINE.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved