2020-08-04 08:05:38 | 8/3/2020 1ST PLUMBING REVIEW **DENIED** WITH COMMENTS |
| NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS |
| TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE |
| GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. |
| |
| 1- SHEET CONTRACT AND ENGINEERING LETTER ARE ILLEGIBLE. |
| SUBMIT CLEAR AND LEGIBLE PLANS FOR REVIEW. WPB |
| AMENDMENTS TO THE FBC SEC. 107.2.1 INFORMATION ON |
| CONSTRUCTION DOCUMENTS. |
| |
| 2- THE BACKFILL UNDER THE SLAB SHALL BE TREATED FOR |
| TERMITES PER THE 2017 FBC B SEC.1816.1 OR 2017 FBC R |
| SEC. 318.1. A TERMITE CERTIFICATE SHALL BE ONSITE FOR A |
| FINAL INSPECTION. |
| |
| 3- PLEASE INDICATE HOW THE PIPES WILL BE PROPERLY |
| SUPORTED UNDER THE HOME |
| |
| 4- PLUMBING REPAIR TUNNEL WORK |
| A CLEAR AND LEGIBLE SANITARY RISER DIAGRAM SHALL BE |
| SUBMITTED SHOWING ALL PIPE SIZES, CONNECTION POINTS TO |
| EXISTING PIPING, HOW THE NEW PIPE WILL BE SUPPORTED, |
| THE TYPE OF ADAPTERS USED FOR THE CONNECTIONS TO |
| EXISTING PIPE, AND THE LOCATIONS OF REQUIRED CLEANOUTS. |
| DETAILS AND BACKFILLING PROCEDURES SHALL BE SUBMITTED |
| THAT CLEARLY SHOW HOW THE STRUCTURAL INTEGRITY OF THE |
| CONCRETE SLAB WILL BE MAINTAINED DURING EXCAVATION AND |
| BACKFILLING. STRUCTURAL FOAM IS NOT PERMITTED FOR |
| BACKFILL BELOW GROUND PER THE FLORIDA BUILDING CODE, |
| RESIDENTIAL, SECTION 318.8 AND THE FLORIDA BUILDING |
| CODE, BUILDING, SECTION 2603.9. |
| |
| WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION & |
| REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| REVISION, MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| COOPERATION. |
| |