Date |
Text |
2021-01-11 09:55:53 | FAILED |
| |
| FACADE IDENTITY SIGN |
| |
| 1) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN |
| CRITERIA PERMIT A MAXIMUM LETTER HEIGHT OF 18 INCHES |
| FOR A FASCIA IDENTITY SIGN UNLESS CITYPLACE RETAIL IS |
| GRANTED A WAIVER II (MINOR PLANNED DEVELOPMENT |
| AMENDMENT) BY THE CITY TO INCREASE THE DIMENSION OF THE |
| SIGN. THE SUBMITTED WAIVER I CANNOT BE USED TO INCREASE |
| THE LETTER DIMENSIONS IN EXCESS OF 18 INCHES IN HEIGHT. |
| IF APPROVED, THE WAIVER II MAY INCREASE THE SIGNS |
| DIMENSION BY UP TO 25 PERCENT, SO THE LETTER HEIGHT |
| COULD THEN BE 22 INCHES TALL AS SHOWN. |
| |
| 2) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN |
| CRITERIA PERMIT A FASCIA IDENTITY SIGNS TO HAVE A |
| MAXIMUM HEIGHT OF 16 FEET FROM FINISHED GRADE. PROVIDE |
| THE DIMENSION LINE TO VERIFY COMPLIANCE. NOTE: ADDING |
| THE PROVIDED DIMENSIONS SHOWS THAT IT EXCEEDS THE |
| PERMITTED 16 FEET. |
| |
| 3) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN |
| CRITERIA REQUIRE THAT REVERSE CHANNEL LETTERS ARE |
| FABRICATED OUT OF ALUMINUM WITH A MINIMUM METAL |
| THICKNESS OF .060 INCHES. PROVIDE THE INFORMATION TO |
| VERIFY THIS REQUIREMENT ON THE PLANS. |
| |
| 4) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN |
| CRITERIA REQUIRE THE STUD MOUNTS TO BE SERIES 316 |
| STAINLESS STEEL ANCHOR BOLTS. PROVIDE VERIFICATION OF |
| THIS REQUIREMENT ON THE PLANS. |
| |
| 5) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN |
| CRITERIA REQUIRE THE SPACERS FOR THE STUD MOUNTS TO BE |
| PAINTED THE COLOR OF THE WALL. PROVIDE VERIFICATION OF |
| THIS REQUIREMENT ON THE PLANS. |
| |
| 6) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN |
| CRITERIA REQUIRES THAT ALL CONDUIT, JUNCTION BOXES, |
| TRANSFORMERS AND OTHER NECESSARY EQUIPMENT IS CONCEALED |
| AND NOT VISIBLE TO THE PUBLIC. PROVIDE VERIFICATION |
| THAT THE POWER SUPPLY BOX AND ITS RELATED COMPONENTS |
| MEET THIS REQUIREMENT. IT APPEARS THEY ARE MOUNTED TO |
| THE INSIDE OF THE WALL AND VISIBLE TO THE PUBLIC ACCESS |
| EASEMENT WITHIN THE PEDESTRIAN ARCADE. |
| |
| PERMITTED: 72 |
| PROPOSED: 8.63 SF |
| |
| STAFF HAS NOTED THAT THE SIGN IS ALREADY INSTALLED, SO |
| THE PENALTY FEE FOR INSTALLING THE SIGN WITHOUT A |
| PERMIT HAS BEEN ADDED. |
| |