2020-07-14 14:36:44 | CODES IN EFFECT: |
| FBC = FLORIDA BUILDING CODE 2017 6TH EDITION |
| WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 |
| 6TH ED, CHAPTER 1. |
| FBC RES = FLORIDA RESIDENTIAL CODE 2017 6TH EDITION |
| FBC PL = FLORIDA PLUMBING CODE 2017 6TH EDITION |
| FS = FLORIDA STATUTES |
| |
| 20061224 422 26TH ST |
| |
| 1ST REVIEW |
| PLUMBING COMMENTS: DENIED |
| |
| 1. THIRD PARTY CERTIFICATION REQUIRED FOR ENGINEER'S |
| DIGITAL SIGNATUR. PER THE WPB AMENDMENTS TO THE FBC, |
| EACH SHEET OF PLAN IS REQUIRED TO BE SIGNED AND SEALED |
| BY THE PERSON RESPONSIBLE FOR THE DESIGN. A DIGITAL |
| PLAN REQUIRES A DIGITAL SIGNATURE WITH THE PROPER THIRD |
| PARTY VERIFICATION. THE DIGITAL SIGNATURE MUST INCLUDE |
| THE STATEMENT "SIGNED AND SEALED" AS PER FAC |
| 61G15-23.004. PROVIDE CORRECTION. WPB FBC 107.1; FS |
| 471/481 |
| |
| 2. RE: HYDRAULIC (TDH) CALCULATIONS; PER WPB FBC 107.2. |
| 1 AND APSP-7-2013, SHALL INCLUDE THE HEAD LOSS FOR EACH |
| OF THE FOLLOWING: THE POOL HEATER, FILTER AND ALL OTHER |
| INLINE APPURTENANCES AS WELL AS THE VALVES AND |
| FITTINGS. PUMP IS NOT INCLUDED IN CALCULATIONS. |
| |
| 3. PER WPB FBC 107.2.1, PROVIDE MANUFACTURER?S |
| SPECIFICATION/INSTALLATION MANUAL FOR ALL POOL |
| EQUIPMENT; PROVIDE PUMP PERFORMANCE CURVE. INLINE |
| EQUIPMENT SPECS IN THE PIPING SYSTEM (IE. FILTER, |
| HEATER, ETC. NEED TO PROVIDE HEAD LOSS TO SHOW WHERE |
| ENGINEER GOT CALCS FOR TDH) |
| |
| 4. PROVIDE SPECS FOR PRIMARY DRAINS AND SKIMMERS. THEY |
| NEED TO BE DESIGNED TO PREVENT ENTRAPMENT. SEE FBC RES |
| R4501.6.6. ENTRAPMENT PROTECTION FOR SUCTION OUTLETS |
| SHALL BE INSTALLED IN ACCORDANCE WITH REQUIREMENTS OF |
| ANSI/APSP/ICC 7. |
| |
| |
| END OF COMMENTS. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| THE PREVIOUSLY REVIEWED SHEETS. |
| |
| ALL PLANS TO BE DIGITALLY SIGNED AND SEALED BY THE |
| DESIGNER IN ACCORDANCE WITH FAC AND FS. |
| |
| |
| |