2020-06-29 11:15:20 | 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 20060703 |
| ADD: 1701 S. FLAGLER DR. # 506 |
| CONT: AOA CONSTRUCTION |
| TEL: 561-660-3504 |
| E-MAIL: [email protected] |
| |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 1ST REVIEW |
| DATE: MON. JUNE 29TH/ 2020 |
| ACTION: DENIED |
| |
| 1) WIND CHART FROM ENGINEERING EXPRESS: |
| 1A) THE WIND CHART FORM ENGINEERING EXPRESS COULD NOT |
| VERIFY THE DIGITAL SIGNATURE. |
| 61G15-23.005 PROCEDURES FOR SIGNING AND SEALING |
| ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES), |
| SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
| FLORIDA ADMINISTRATIVE CODE 61G15-23.005 (3)(C) A |
| SCANNED, FACSIMILE, DIGITALLY CREATED OR COPIED IMAGE |
| OF THE LICENSEE?S SIGNATURE SHALL NOT BE USED ON |
| DIGITALLY SIGNED AND SEALED ENGINEERING PLANS, |
| SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. |
| |
| 1B) THE SUBMITTED WIND CHART FROM ENGINEERING EXPRESS |
| IS ONLY GOOD FOR BUILDINGS < (LESS THAN 60 FEET). THIS |
| HIGHRISE IS APPROXIMATELY 230 FEET ABOVE GRADE. NOTE TO |
| CONTRACTOR NEGATIVE PRESSURES FOR COMPONENTS AND |
| CLADDING ARE ALWAYS TAKEN FROM THE MRH (MEAN ROOF |
| HEIGHT). 2017 FBC-B TABLE 1609.7(2) ADJUSTMENT FACTORS |
| FOR HEIGHT & EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR |
| THE BUILDING. |
| 1C) ) THE SUBMITTED WIND CHART FROM ENGINEERING EXPRESS |
| NEITHER ARE THE WALL ZONES IDENTIFIED ON THE SIDE |
| ELEVATIONS AND ON THE PRESSURE CHARTS OPENING SIZES AND |
| PRESSURES ARE NOT IDENTIFIED. |
| 2) THE SUBMITTED PRODUCT APPROVALS DIDN?T HAVE THE |
| FOLLOWING INFORMATION IDENTIFIED. PLEASE IDENTIFY ON |
| THE PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF |
| RECORD AND BEFORE SUBMISSION TO THE BUILDING |
| DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE |
| IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING, |
| MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED |
| INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE |
| PRESSURES FOR EACH OPENING SIZE. 2017 FBC-B 1405.13.1 |
| INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN |
| ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS. |
| FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH |
| INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM |
| LOADS AND SPACING USED IN THE TESTS. |
| 3) PLEASE NOTE THE FOLLOWING 3 FILES WERE LOADED WRONG, |
| FAILED TO OPEN: |
| 3.1) 1XFRVUM1.RJI |
| 3.2) JOOOE3PQP.WZH |
| 3.3) RBV4W5R5.PZN |
| YOU MAY HAVE TO CONTACT THE PERMIT LIBRARIANS: |
| LAURA MARCHANT 561-805-6658 |
| OR CAROLINA CARVAJAL 561-805-6690 |
| |
| 4) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE |
| THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED |
| DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE |
| MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS |
| AND INFORMATION LACKING UNDER THE PRIOR REVIEW. |
| |
| PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID |
| 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS |
| 561-718-9724. |
| JAMES A. WITMER BN, PX, SFP, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |