2020-06-16 17:10:12PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE STAIR #1 AND # 2 PLAN VIEWS ON SHEET SD-01 DO
 NOT APPEAR TO SHOW COMPLIANCE WITH FBC ACCESSIBILITY
 SECTION 505.10.3 FOR THE HANDRAIL EXTENSION AT THE
 BOTTOM OF THE STAIRS. THE HANDRAIL IS REQUIRED TO
 EXTEND AT THE SLOPE OF THE STAIR FLIGHT FOR A
 HORIZONTAL DISTANCE EQUAL TO ONE TREAD DEPTH BEYOND THE
 LAST RISER NOSING. IT CAN THEN RETURN TO A GUARD, A
 WALL OR THE LANDING. THE DRAWING APPEARS TO SHOW THE
 HANDRAIL MAKING A 90 DEGREE TURN AND EXTENDING FOR 12"
 PERPENDICULAR TO THE STAIRS.