2020-10-27 11:57:10 | 2017 FBC- BUILDING PLAN REVIEW |
| W. P. B. PERMIT: 20060456 |
| ADD: 1101 N. OLIVE AVE. |
| CONT: S. D. CHURCH & SONS |
| TEL:1- 386-314-3001 |
| E-MAIL: [email protected] |
| |
| 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH |
| AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| ADMINISTRATION |
| |
| 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| BUILDING CODE, BUILDING. |
| |
| 2ND REVIEW |
| DATE: TUES. AUGUST 25TH / 2020 |
| ACTION: DENIED |
| |
| 1) COMPLIED. ACCESSIBLE PARKING AND ACCESS AISLE. |
| |
| 2) COMPLIED. LIFE SAFETY PLAN 1ST FLOOR & 2ND FLOOR. |
| |
| 3) COMPLIED/ VERTICAL ACCESSIBILITY/ DISPROPORTIONATE |
| COST. |
| |
| 4)SEMI- COMPLIED, ADDITIONAL COMMENTS. SPOKE WITH THE |
| CONTRACTOR ABOUT THE REQUIRED 20% DISPROPORTIONATE COST |
| LETTER ON THE COMPANY LETTER HEAD AND WHAT ITEMS CAN BE |
| INCLUDED UNDER THE 20% DISPROPORTIONATE COST. THE FIRST |
| FLOOR SHOWS VARIOUS AREAS WHERE ACCESSIBLE UPGRADES ARE |
| GOING TO BE MADE BUT THE 2ND FLOOR DOES SHOW |
| ALTERATIONS TO THE 2ND FLOOR. THE RESTROOM 2 AND THE |
| PRIVATE BATHROOM AS WELL AS DOORS TO THE RESTROO#2 AND |
| PRIVATE BATHROOM. |
| |
| WHEN YOU REMODEL A ELEMENT AS DOORS AND OR RESTROOMS |
| AND OR BATHROOMS THEN THEY HAVE TO BE BROUGHT UP TO THE |
| CURRENT CODE STANDARDS. 2017 EXISTING BUILDING CODE. |
| 801.3 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, |
| COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE |
| REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING. |
| UNDER THE EXISTING BUILDING CODE EACH PORTION OF THIS |
| CODE LEVEL I, LEVEL 2 OR LEVEL 3 ALL REFER BACK TO THE |
| ACCESSIBILITY CODE. IF ELEMENTS ARE NOT TOUCHED THEN |
| THEY CAN STAY AS THEY ARE. THE DISPROPORTIONATE COST |
| KICKS IN TRYING TO MAKE THE BUILDING OVER A SERIES OF |
| SMALLER RENOVATIONS. YOU SHOW HOW YOU HAVE MET THE |
| DISPROPORTIONATE COST FOR THE VERTICAL ACCESSIBILITY, |
| BUT THAT DOES NOT RELIEVE YOU FROM UPGRADING THE 2ND |
| FLOOR WHERE WORK IS SHOWN TO BE PREFORMED. |
| |
| |
| DISPROPORTIONATE COST. PLEASE REVIEW HOW YOU ARE TO |
| MEET DISPROPORTIONATE COST. EITHER THE CONTRACTOR OR |
| THE DESIGNER OF RECORD ON THEIR LETTERHEAD NEED TO SHOW |
| HOW THEY ARE GOING TO SPEND THE 20% DISPROPORTIONATE |
| FUNDS LISTED FOR EACH ELEMENT WHERE THE FUNDS ARE BEING |
| SPENT AND IN THE ORDER LISTED IN SECTION 202.4.1 |
| DISPROPORTIONATE COST OF THE 2017 ACCESSIBILITY CODE. |
| |
| 5A-C) COMPLIED. |
| |
| 5D)SEMI-COMPLIED. SHEET A-3 DOES NOT SHOW A HIGH- LOW |
| DRINKING FOUNTAIN. THE 1ST AND 2ND FLOOR COMBINED |
| OCCUPANT LOAD IS 27 OCCUPANTS REQUIRING DRINKING |
| FOUNTAINS. THE FLOOR PLAN DOES SHOW A HIGH/ LOW |
| DRINKING FOUNTAIN AND 30X 48 CLEAR FLOOR SPACE. SHEET |
| A4 SHOWS ELEVATIONS FOR ELEMENTS WITHIN THE RESTROOMS |
| BUT MISSING ELEVATIONS FOR THE DRINKING FOUNTAIN AND |
| COMPLIANCE WITH: |
| |
| DRINKING FOUNTAINS. |
| 5D)(1) 2017 FBC-ACCESSIBILITY CODE. 211.2 MINIMUM |
| NUMBER. NO FEWER THAN TWO DRINKING FOUNTAINS SHALL BE |
| PROVIDED. ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 |
| THROUGH 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY |
| WITH 602.7. SHOW ELEVATION VIEW WITH SPOUT HEIGHTS. |
| |
| 5D)(2) PROTRUDING OBJECTS 307.2 PROTRUSION LIMITS |
| 307.2. OBJECTS WITH LEADING EDGES MORE THAN 27 INCHES |
| AND NOT MORE THAN 80 INCHES ABOVE THE FLOOR SHALL NOT |
| PROTRUDE MORE THAN 4 INCHES HORIZONTALLY INTO THE |
| CIRCULATION PATH. SHOW WITH ELEVATION VIEW, DOES THIS |
| TYPE OF DRINKING FOUNTAIN THE BOTTOM OF THE SHROUD LESS |
| THAN 27 INCHES OFF THE FLOOR FOR BOTH HIGH & LOW |
| DRINKING FOUNTAINS? |
| |
| 5D)(3) COMPLIED. 30X48 CLEAR FLOOR SPACE. |
| |
| 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| |
| PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID |
| 19 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS |
| 561-718-9724. |
| |
| JAMES A. WITMER BN, PX, SFP, CBO |
| SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT |
| 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 |
| TEL: 561-805-6717 |
| FAX: 561-805-6676 |