Date |
Text |
2020-07-02 08:51:46 | 1ST REVIEW FBC-2017 PLUMBING |
| PERMIT- 20060456 |
| 7/2/2020 |
| |
| CODES IN EFFECT: |
| FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017 |
| FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017 |
| FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| 2017 |
| FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| 2017 |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| EDITION 2017 |
| |
| PLAN REVIEW RESULTS: DENIED. |
| |
| 1) SHEET P1: THE SINK FIXTURE DRAIN MUST CONNECT TO THE |
| 3" BUILDING DRAIN DOWNSTREAM OF THE WC AND LAVATORY PER |
| SECTIONS 912.1 AND 912.2.1 FBC P. |
| |
| 2) P1: PROVIDE A WATER RISER DRAWING SHOWING PIPE |
| SIZES, LOCATIONS OF SHUTOFF VALVES, WATER HAMMER |
| ARRESTORS, MIXING VALVES ETC.- SECTION 107.3.5.1.3 WPB |
| AMENDMENTS TO THE FBC. |
| |
| 3) P1: PROVIDE A PLUMBING FIXTURE AND DEVICE SCHEDULE- |
| SECTION 107.2.1 WPB & SECTION 405.9 FBC P. |
| |
| 4) P1: PROVIDE PLUMBING FIXTURE CALCULATIONS FOR THE |
| PROPOSED ALTERATIONS PER TABLE 403.3 FBC P. PROVIDE A |
| SCHEDULE INDICATING THE REQUIRED AND PROVIDED PLUMBING |
| FIXTURES. PLEASE NOTE THAT THE PLAN DOES NOT INDICATE |
| DRINKING FOUNTAINS, OR A SERVICE SINK ARE EITHER |
| EXISTING OR PROPOSED. REFER TO SECTION 211.1- 211.3 FBC |
| ACC FOR ACCESSIBLE DRINKING FOUNTAIN REQUIREMENTS. |
| REVISE THE PLANS TO SHOW COMPLIANCE. |
| |
| 5) P1: INDICATE HOW TEMPERED WATER WILL BE PROVIDED TO |
| THE LAVATORY- SECTION 416.5 FBC P. |
| |
| 6) A4: ACCESSIBILITY CORRECTIONS- FBC ACC: |
| A) LENGTH OF THE LAVATORY CLEAR FLOOR SPACE NOT SHOWN- |
| SECTION 606.2 AND 305. |
| B) HEIGHT TO THE TOP OF THE WATER CLOSET SEAT FROM THE |
| FINISHED FLOOR INDICATED AT 20"- SECTION 604.4 |
| C) THE SIDE GRAB BAR AT THE WATER CLOSET SHALL EXTEND |
| MINIMUM 54" FROM THE REAR WALL- FIGURE 604.5.1. |
| D) REAR GRAB BEHIND WATER CLOSET NOT CENTERED |
| CORRECTLY- FIGURE 604.5.2. |
| E) HEIGHTS OF GRABS SHOWN AT BOTH 33" AND 36" FROM |
| FLOOR. GRAB BARS SHALL BE INSTALLED AT 33" MINIMUM AND |
| 36"MAXIMUM MEASURED FROM THE FINISHED FLOOR TO THE TOP |
| OF THE GRIPPING SURFACE- SECTION 609.4. |
| F) FLUSH CONTROL SHOWN ON THE WRONG SIDE OF THE WATER |
| CLOSET- SECTION 604.6 |
| G) TOILET PAPER DISPENSER NOT LOCATED IN COMPLIANCE |
| WITH- SECTION 604.7. |
| H) HEIGHT OF THE MIRROR SHALL BE 40" FROM THE FINISHED |
| FLOOR TO THE BOTTOM OF THE REFLECTIVE SURFACE SECTION |
| 603.3. |
| I) KNEE AND TOE CLEARANCES FOR THE LAVATORY NOT SHOWN- |
| SECTIONS 305 & 306. |
| |
| 7) A2, A3, & A4: NO ACCESSIBILITY DETAILS HAVE BEEN |
| PROVIDED FOR THE ALTERED SECOND FLOOR BATHROOM. THE |
| CONFIGURATION OF THE ROOM INDICATES NON-COMPLIANCE. |
| PLEASE PROVIDE ENLARGED DRAWINGS AND DETAILS TO SHOW |
| COMPLIANCE WITH THE FBC ACC: |
| A) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE |
| WATER CLOSET- SECTION 604.3. |
| B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE |
| LAVATORY- SECTION 606.2. |
| C) DIAGRAMS AND DIMENSIONS FOR THE NEW SHOWER PER |
| SECTION 608.2.1 AND FIGURE 608.2.1. THE SHOWER |
| COMPARTMENT SHALL BE 36 INCHES BY 36 INCHES CLEAR |
| INSIDE DIMENSIONS MEASURED AT THE CENTER POINTS OF |
| OPPOSING SIDES AND SHALL HAVE A 36 INCH WIDE MINIMUM |
| ENTRY ON THE FACE OF THE SHOWER COMPARTMENT. CLEARANCE |
| OF 36 INCHES WIDE MINIMUM BY 48 INCHES LONG MINIMUM |
| MEASURED FROM THE CONTROL WALL SHALL BE PROVIDED. |
| D) BATHROOM ENTRY DOOR WIDTH, DOOR SWING, AND |
| WHEELCHAIR APPROACHES- SECTION 604.8.1.2 & 604.8.1.3. |
| E) TURNING SPACE DIAMETERS SECTION 304.3. |
| F) CENTERLINE OF THE WATER CLOSET FROM THE SIDE WALL- |
| SECTION 604.2. |
| G) HEIGHT OF THE WATER CLOSET SEAT FROM THE FINISHED |
| FLOOR- SECTION 604.4. |
| H) HEIGHT OF THE FRONT RIM OF THE LAVATORY FROM THE |
| FINISHED FLOOR- SECTION 606.3 |
| I) KNEE AND TOE CLEARANCES FOR THE LAVATORY- SECTION |
| 306. |
| J) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB |
| BARS- SECTION 604.5 |
| K) LOCATION OF THE WATER CLOSET FLUSH CONTROL- SECTION |
| 604.6. |
| L) LOCATION, CLEARANCE, AND MOUNTING HEIGHT FOR THE |
| TOILET PAPER DISPENSER- SECTION 604.7. |
| M) HEIGHT OF THE MIRROR FROM THE FINISHED FLOOR TO THE |
| BOTTOM OF THE REFLECTIVE SURFACE- SECTION 603.3 |
| N) NEW SHOWER GRAB BAR AND SHOWER CONTROL LOCATIONS AND |
| CLEARANCES PER SECTIONS AND FIGURES 608.3.1 & 608.5.1. |
| O) LOCATION AND DETAILS FOR INSTALLATION OF THE |
| REQUIRED SEAT IN THE SHOWER- SECTION 608.4 & 610.3. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. |
| |
| CHRISTOPHER L. COLE |
| MECHANICAL/PLUMBING PLANS EXAMINER |
| 401 CLEMATIS STREET |
| WEST PALM BEACH FL 33401 |
| 561-805-6719 |
| CCOLE@WPB |
| |