2020-07-29 09:03:11WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20060393
 ADD: 2405 MERCER AVE.
 CONT: BUTLER CONSTRUCTION
 TEL: 561-832-9700
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. JULY29TH/ 2020
 ACTION: DENIED
  
 1) 2ND REQUEST. THE PERMIT APPLICATION STATES THE WORK
 TO BE ACCOMPLISHED UNDER THE SCOPE OF THIS PERMIT IS
 FOR THE RENOVATION OF AN EXISTING RESTROOM FOR A VALUE
 OF $5,000.00 DOLLARS.
  
 2A) 2ND REQUEST. SHEET A-2 STILL MAKES REFERENCE TO THE
 2014 FBC.
  
 2B) NEW COMMENT. THIS PLAN STATES THAT THE ALTERATION
 LEVEL IS LEVEL II. THE CITY OF WEST PALM BEACH BUSINESS
 TAX (OLD OCCUPATIONAL LICENSING) SHOWS THIS SPACE BEING
 CARLYLE THERAPY ASSOCIATION WHICH IS A BUSINESS
 OCCUPANCY. A CHANGE OF OCCUPANCY IS OCCURRING.
 THE DESIGNER OF RECORD HAS NOT MET ALL OF THE
 REQUIREMENTS FOUND UNDER COMMENT 468.1 FOR EDUCATIONAL
 OCCUPANCIES. ALL OF THE REQUIREMENTS, THERE IS NO
 EXISTING BUILDING CODE FOR THIS OCCUPANCY GROUP.
  
 3) COMPLIED.
  
 4) SHEET A-2 MAKE REFERENCE TO THIS FACILITY TO BE A
 PUBLIC CHARTER SCHOOL GRADES K-8TH GRADE. PLEASE BE
 AWARE OF THE 2017 FBC-EXISTING CODE SCOPING
 REQUIREMENTS AND EXCEPTION FOUND UNDER SECTION 101.2.
 EXCEPTION: FOR THE PURPOSE OF PUBLIC EDUCATION AND
 STATE LICENSED FACILITIES, SEE CHAPTER 4 SPECIAL
 OCCUPANCIES OF THE FLORIDA BUILDING CODE, BUILDING.
 SECTION 453 DEALS WITH STATE REQUIREMENTS FOR
 EDUCATIONAL FACILITIES. NOT THE LOCAL BUILDING DEPART.
 CONCERN UNLESS THE SCHOOL BOARD SUBMITS PLANS FOR
 PUBLIC SCHOOLS.
 4A)(1) CHAPTER 468 FOR FLORIDA?S PUBLIC & PRIVATE
 SCHOOLS, COLLEGES AND UNIVERSITIES. THERE IS NO
 EXISTING BUILDING CODE TO GO BY UNDER SPECIAL
 OCCUPANCIES FOUND IN CHAPTER 4. CHAPTER 468 IN ITS
 ENTIRITY HAS TO SHOW COMPLIANCE.
  
 4A)(2) SEMI-COMPLIED. THERE IS NOT ENOUGH INFORMATION
 ON THE PLAN TO DETERMINE CODE COMPLIANCE FOR THE
 REQUIRED NUMBER OF FIXTURES REQUIRED UNDER THE 2017
 FBC-B TABLE 2902.1 FOR EDUCATION. THE SUBMITTED TABLE
 GIVES A OVERALL COUNT BUT NOT BY AGE GROUP SEE THE 2017
 ACCESSIBILITY CODE 604.9 AGES 5-8 AGES 9-12 FOR WATER
 CLOSET CENTERLINE, TOILET SEAT HEIGHT, GRAB BAR HEIGHT
 AND DISPENSER HEIGHT.
  
 4B) 2ND REQUEST ACCESS. CODE TABLE 604.9.THE 2017 FBC-B
 468.3.5.1 STANDARDS. EDUCATIONAL AND ANCILLARY
 FACILITIES SHALL BE PROVIDE WITH TOLIETS, HAND WASHING
 AND DRINKING FOUNTAINS FOR ALL OCCUPANTS IN RATIOS AND
 ACCESSIBLE AS REQUIRED BY THE FLORIDA BUILDING CODE,
 FLORIDA LAWS AND FEDERAL REGULATIONS. SHEET A-1 & A2
 SHOWS A SINGLE DRINKING FOUNTAIN, PLEASE SHOW A DOUBLE
 HIGH/ LOW, PLEASE SEE IN THE 2017 FBC-ACCESSIBILITY
 CODE REQUIREMENTS FOR DRINKING FOUNTAINS. SHEET A-3
 SHOWS COMPLIANCE WITH :
  
 2017 FBC-ACCESSIBILITY CODE. 211.2 MINIMUM NUMBER. NO
 FEWER THAN TWO DRINKING FOUNTAINS SHALL BE PROVIDED.
 ONE DRINKING FOUNTAIN SHALL COMPLY WITH 602.1 THROUGH
 602.6 AND ONE DRINKING FOUNTAIN SHALL COMPLY WITH
 602.7.
  
 NOT SHOWN IN COMPLIANCE. PROTRUDING OBJECTS 307.2
 PROTRUSION LIMITS 307.2. OBJECTS WITH LEADING EDGES
 MORE THAN 27 INCHES AND NOT MORE THAN 80 INCHES ABOVE
 THE FLOOR SHALL NOT PROTRUDE MORE THAN 4 INCHES
 HORIZONTALLY IN TO THE CIRCULATION PATH.
  
 60.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING
 WITH 305, POSITIONED FOR A FORWARD APPROACH, AND KNEE
 AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED.
  
 5) COMPLIED. SHEET A-3 GRAB BARS.
  
 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 A THOROUGH REVIEW OF THE PLANS COULD NOT HAPPEN SINCE
 THERE WAS A GREAT DEFICIENCY IN PLANS AND REQUIRED
 DOCUMENTATION. WITH THE NEXT PLAN REVIEW CYCLE THERE
 MAYBE ADDITIONAL REVIEW COMMENTS BECAUSE OF NEW PLANS
 AND INFORMATION LACKING UNDER THE PRIOR REVIEW.
  
 PLEASE NOTE WE ARE WORKING FROM HOME BECAUSE OF COVID
 19
 IF YOU WOULD LIKE TO CONTACT ME, MY CELL NUMBER IS
 561-718-9724.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  