Plan Review Notes For Permit 20060348 |
Permit Number |
20060348 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2020-06-24 12:39:52 | PARKING LOT EXPANSION | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) DRAWING E-002 SHOWS CODE USED FOR DESIGN AS FBC 2014 | | - SHOULD BE FBC 2017 | | 2) PLEASE SHOW ACCESSIBLE PARKING SPACE SIZE TO COMPLY | | WITH FBC ACCESSIBILITY 502.2 | | 3) PLEASE SHOW ACCESSIBLE PARKING ACCESS AISLE SIZE AND | | STRIPPING TO COMPLY WITH FBC ACCESSIBILITY 502.3 | | 4) PLEASE SHOW ACCESSIBLE PARKING SIGNAGE TO COMPLY | | WITH FBC ACCESSIBILITY 502.6.1 | | 5) PLEASE PROVIDE SIGNED AND SEALED LIGHT POLE DETAILS | | (FOUNDATION AND ATTACHMENTS TO THE FOUNDATION ALSO SHOW | | THE WIND DESIGN PARAMETERS USED) FROM AN ARCHITECT OR | | ENGINEER TO COMPLY WITH WIND LOADS PER FBC 1609 | | |
|