Plan Review Notes
Plan Review Notes For Permit 20050907
Permit Number 20050907
Review Stop B
Sequence Number 1
Notes
Date Text
2020-06-01 09:19:29PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE HORIZONTAL ROLLING WINDOWS IN THE BEDROOMS THAT
 ARE MARKED EGRESS DO NOT APPEAR TO COMPLY WITH FBC-R
 310 FOR THE REQUIRED CLEAR OPENING WIDTH OF 22 INCHES.
 FBC-R 310.2.5 ALLOWS REPLACEMENT WINDOWS THAT ARE THE
 MANUFACTURER'S LARGEST STANDARD SIZE THAT WILL FIT IN
 THE ROUGH OPENING AND IS THE SAME OPERATING STYLE AS
 THE EXISTING WINDOW OR A STYLE THAT PROVIDES EQUAL OR
 GREATER OPENING AREA THAN THE EXISTING WINDOW. EXPLAIN
 HOW THIS REQUIREMENT IS BEING MET.
  
  