Plan Review Notes
Plan Review Notes For Permit 20050893
Permit Number 20050893
Review Stop B
Sequence Number 1
Notes
Date Text
2020-06-08 16:23:422017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 20050893
 ADD: 2995 45TH ST.
 CONT: TBD/ TO BE DETERMINED
 TEL: ???
 E-MAIL: ???
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: MON. JUNE 08/2020
 ACTION: DENIED
  
  
 1) SUBMITTED ARE 31 PAGES OF VARIOUS DETAILS BUT NONE
 OF THE DETAILS SHOW A FLOOR PLAN NOR ELEVATION PLAN OF
 THE DUMPSTER WITH CUT SECTIONS THROUGH THE FOUNDATION
 AND SLAB NOR THROUGH THE WALL OF THE DUMPSTER. NO
 ARCHITECTURAL NOR STRUCTURAL SHEETS.
 2017 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATIVE CODE 107.3.5 MINIMUM
 PLAN REVIEW CRITERIA FOR BUILDINGS/ STRUCTURES.
 107.3.5.1. COMMERCIAL BUILDINGS.
 107.3.5.1.1. BUILDINGS.
 FLOOR PLAN ELEVATIONS WITH CUT SECTIONS THROUGH THE
 SLAB AND FOUNDATION.
 ELEVATIONS OF THE SIDE WALLS, ALSO SHOW COMPLIANCE WITH
 CUT SECTIONS OF THE WALLS PROVIDING
 COMPONENTS OF THE MAIN WIND FORCE RESISTING SYSTEMS.
 FROM FOOTER TO THE TOP OF THE EITHER BOND BEAM OR
 POURED BEAM.
 PLEASE PROVIDE A ELEVATION OF THE GATE WAY AND PROVIDE
 THE CLEAR WIDTH OF THE OPENING.
  
 2) PLEASE PROVIDE THE WIND DESIGN CRITERIA FOR THIS
 STRUCTURE. 2017 FBC-B 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 2.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS
 DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1.
  
 2.2. RISK CATEGORY.
  
 2.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2.
 HEIGHT AND EXPOSURE. ASCE 7-10 TABLE 30.3.1.
  
 2.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 2.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENTS AND CLADDING MATERIALS SPECIFICALLY DESIGNED
 BY THE REGISTERED DESIGN PROFESSIONAL RESPONSIBLE FOR
 THE DESIGN OF THE STRUCTURE, PSF.
  
 2.6. TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE BUILDING
 1609.3.1 WIND SPEED CONVERSION VULT TO VASD.
  
 3) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
 PLEASE NOTE WE ARE WORKING FROM HOME IF YOU WOULD LIKE
 TO CONTACT ME, MY CELL NUMBER IS 561-718-9724.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 BUILDING DIVISION / DEVELOPMENT SERVICES DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  