Plan Review Notes
Plan Review Notes For Permit 20050732
Permit Number 20050732
Review Stop P
Sequence Number 1
Notes
Date Text
2020-06-25 13:12:031ST REVIEW FBC-2017 PLUMBING
 PERMIT- 20050732
 6/25/2020
  
 CODES IN EFFECT:
  
 FBC P- FLORIDA PLUMBING CODE SIXTH EDITION 2017
 FBC ACC- FLORIDA ACCESSIBILITY CODE SIXTH ADDITION 2017
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017
 FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION
 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET 1.1: PROVIDE A PLUMBING FIXTURE CALCULATION
 SCHEDULE ON THE PLAN- TABLE 403.3 FBC P. SHOW THE
 REQUIRED AND PROVIDED FIXTURES IN THE SCHEDULE. PLEASE
 NOTE A DRINKING FOUNTAIN IS REQUIRED FOR A2
 OCCUPANCIES. REFER TO SECTION 410 FBC P, AND SECTIONS
 211 AND 602 FBC ACC FOR FURTHER INFORMATION AND CODE
 COMPLIANCE REQUIREMENTS.
  
 2) SHEET 1.1: CORRECT THE NOTE AT THE TOILET ROOM
 INDICATING 30"X48" CLEAR FLOOR SPACE AT THE WATER
 CLOSET. CLEARANCE AROUND WATER CLOSETS SHALL BE 60
 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE
 WALL AND 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM
 THE REAR WALL- SECTION 604.3.1 FBC ACC.
  
 3) SHEET 1.1: THE MOUNTING LOCATIONS AND HEIGHTS SHOWN
 IN THE TOILET ACCESSORY SCHEDULE ARE NOT IN COMPLIANCE
 WITH THE FBC ACC. IN ORDER TO EXPEDITE THE REVIEW
 PLEASE PROVIDE ENLARGED DIMENSIONED DETAILS AND
 ELEVATION VIEWS INDICATING:
 A) CLEAR FLOOR SPACE DIMENSIONS FOR THE WATER CLOSETS-
 SECTION 604.3 FBC ACC.
 B) CLEAR FLOOR SPACE DIMENSIONS FOR THE LAVATORIES-
 SECTION 606.2
 C) CENTERLINES OF THE WATER CLOSETS FROM THE SIDE WALLS
 OR PARTITIONS- SECTION 604.2.
 D) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED
 FLOORS- SECTION 604.4.
 E) HEIGHTS OF THE FRONT RIM OF THE LAVATORY FROM THE
 FINISHED FLOOR- SECTION 606.3
 F) KNEE AND TOE CLEARANCES FOR THE LAVATORIES- SECTION
 306.
 G) LOCATIONS, LENGTHS, AND MOUNTING HEIGHTS OF GRAB
 BARS- SECTION 604.5
 H) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS-
 SECTION 604.6.
 I) LOCATIONS, CLEARANCES, AND MOUNTING HEIGHTS FOR
 PAPER DISPENSERS- SECTION 604.7
 J) HEIGHTS OF THE MIRROR FROM THE FINISHED FLOOR TO THE
 BOTTOM OF THE REFLECTIVE SURFACES- SECTION 603.3.
  
 4) SHEET 4.1: PROVIDE A PLUMBING FIXTURE SCHEDULE-
 SECTION 406 FBC P.
  
 5) 4.1: PROVIDE AN EQUIPMENT SCHEDULE FOR THE WATER
 HEATER INDICATING MAKE AND MODEL, GALLON SIZE, AND
 EFFICIENCY RATING- SECTION 502.1 FBC P, AND TABLE 404.2
 FBC ACC.
  
 6) 4.1: PROVIDE EQUIPMENT SCHEDULES FOR THE WATER
 RECIRCULATING PUMP, AND THE THERMAL EXPANSION TANK-
 SECTION 607.3 FBC P. EXPAND THE WATER HEATER PIPING
 DIAGRAM TO SHOW THE LOCATIONS AND PIPING CONNECTIONS
 FOR THE RECIRC. PUMP AND EXPANSION TANK- SECTIONS 607.2
 & 607.3 FBC P.
  
 7) 4.1, WATER RISER: SHOW WATER SUPPLY CONNECTIONS TO
 THE ICE MAKER, AND ANY OTHER HARD PIPED BEVERAGE
 DISPENSERS OR EQUIPMENT- SECTION 107.2.1 WPB.
  
 8) 4.1: PROVIDE A PLUMBING DEVICE SCHEDULE INDICATING
 MAKES AND MODELS, AND LISTING AND LABELING FOR THE
 MIXING VALVE, REQUIRED WATER HAMMER ARRESTORS, AND
 BACKFLOW PREVENTERS- SECTIONS 604.9, 607.1.2, AND 608.3
 FBC P. SHOW ALL DEVICE LOCATIONS ON THE WATER RISER.
 9) PLEASE PROVIDE A KITCHEN EQUIPMENT PLAN AND SCHEDULE
 FOR THE KAVA COOKING AND DISPENSING OPERATION- SECTION
 107.2.1 WPB.
  
 10) REFER TO SECTIONS 1003.3.1 AND 1003.3.4 FBC P: A
 GREASE INTERCEPTOR WILL BE REQUIRED FOR THE KAVA BAR.
 PLEASE REVISE THE PLUMBING PLANS TO SHOW THE DRAINAGE
 CONNECTIONS TO THE INTERCEPTOR, PROVIDE SIZING
 CALCULATIONS, AND AN EQUIPMENT SCHEDULE ON THE PLAN.
 PLEASE NOTE THAT A SEPARATE PERMIT WILL BE REQUIRED FOR
 EXTERIOR IN-GROUND INSTALLATIONS- SEC 90-125 CITY OF
 WPB CODE OF ORDINANCES
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  