Plan Review Notes For Permit 20050025 |
Permit Number |
20050025 |
|
Review Stop |
R |
Sequence Number |
2 |
|
Notes |
Date |
Text |
2020-07-01 16:35:08 | BUILDING PROVISO/ DEFERRED SUBMITTALS: | | ROOFING PERMIT AND PRODUCT APPROVAL WILL BE SUBMITTED | | AFTER PERMIT ISSUANCE. FOR ALL ROOFING PRODUCTS PLEASE | | IDENTIFY ALL ROOFING SUB-SYSTEMS AND THEIR ASSOCIATED | | PRESSURES FOR ROOF ZONE # 1. REVIEW THE PRODUCT | | APPROVAL LIMITATIONS, IF ENHANCED FASTENING IS ALLOWED | | FOR ROOF ZONES 2 & 3. FASTENER DENSITIES SHALL BE | | INCREASED FOR BOTH INSULATION & THE BASE SHEET AS | | CALCULATED IN COMPLIANCE WITH ROOFING APPLICATION | | STANDARDS RAS 117. CALCULATION PREPARED, SIGNED AND | | SEALED BY A FLORIDA REGISTERED PROFESSIONAL ENGINEER OR | | REGISTERED ARCHITECT. 1609.6.4.4.1 COMPONENTS & | | CLADDING. | | |
|