Date |
Text |
2020-06-15 12:16:59 | 1) SHOW ALL THE NEW AND RELOCATED PLUMBING FIXTURES ON |
| THE WATER RISER. WPB AMEND. TO FBC SEC. 107.3.5.1.3. |
| 2) THE TOILET ROOM DOOR APPEARS TO SWING INTO THE CLEAR |
| FLOOR SPACE FOR THE DRINKING FOUNTAIN. DOORS SHALL NOT |
| SWING INTO THE CLEAR FLOOR SPACE OR CLEARANCE REQUIRED |
| FOR ANY FIXTURE PER 2017 FBC-ACCESS. SEC.602.2.3. |
| 3) SHT. MP.1 - NEW BATH SANITARY RISER - THE WASHING |
| MACHINE CANNOT DISCHARGE INTO A HORIZONTAL WET VENT PER |
| FBC-PLUMBING SEC.912.1. THE WASHING MACHINE SHALL |
| CONNECT TO THE HORIZONTAL DRAIN DOWNSTREAM OF THE WATER |
| CLOSET. |
| 4) SHT.MP-1 - 1ST FLOOR BATH SANITARY RISER - THE |
| DRINKING FOUNTAIN AND THE SINK CANNOT DISCHARGE INTO A |
| HORIZONTAL WET VENT PER 2017 FBC-PLUMBING SEC. |
| 912.1.THE DRINKING FOUNTAIN AND FUTURE SINK SHALL |
| CONNECT TO THE HORIZONTAL DRAIN DOWNSTRAM OF THE STACK |
| TO THE 2ND FLOOR. |
| 5) IN ORDER TO UTILIZE AN AIR ADMITTANCE VALVE THERE |
| MUST BE A MINIMUM OF ONE STACK VENT OR VENT STACK |
| EXTENDED TO THE OUTDOORS TO THE OPEN AIR PER |
| FBC-PLUMBING SEC.918.7. SHOW COMPLIANCE ON THE PLANS. |
| 6) SUBMIT A DETAIL OF THE DRYWELL FOR THE CONDENSATE |
| LINE. |
| 7) SHOW THE SHOWER DIMENSIONS ON THE PLANS. COMPLY WITH |
| FBC-PLUMBING SEC. 417.4. |
| 8) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE |
| TANKLESS WATER HEATERS. WPB AMEND. TO FBC SEC. 107.2.1. |
| 9) SHOW BOTH TANKLESS WATER HEATERS ON THE WATER RISER |
| ALONG WITH ALL CONNECTED FIXTURES. WPB AMEND. TO FBC |
| SEC. 107.2.1. |
| 10) THE SANITARY RISER SHOWS A 1 INCH DRAIN FOR THE |
| DRINKING FOUNTAIN. CLARIFY. |
| 11) SHT. A.1 - TOILET ACCESSORY SCHEDULE AND ELEVATIONS |
| - THE GRAB BARS SHALL BE MEASURED TO THE TOP OF THE |
| GRIPPING SURFACE PER FBC-ACCESS. SEC.609.4. |
| 12) SHT. A.1 - THERE IS A NOTE BY THE GRAB BAR |
| INSTALLATION DETAIL THAT REFERENCES THE 2010 FBC. |
| DELETE THIS NOTE. |
| 13) SHT. A.1 - TYPICAL TOILET ROOM PLAN SHOWS THE |
| CCLEAR FLOOR SPACE FOR THE WATER CLOSETAS 56 INCHES |
| WIDE BY 60 INCHES DEEP.THE CLEAR FLOOR SPACE SHALL BE |
| 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE |
| WALL AND 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM |
| THE REAR WALL PER FBC-ACCESS. SEC.604.3.1. |
| 14) THE TOILET PAPER HOLDER SHALL BE LOCATED IN |
| ACCORDANCE WITH FBC-ACCESS. SEC.604.7. SHOW THE |
| DIMENSIONS ON THE PLANS. |
| |
| TIM LARGE |
| CHIEF PLUMBING INSPECTOR |
| CITY OF WEST PALM BEACH BUILDING DIVISION |
| 401 CLEMATIS ST. |
| P.O. BOX 3147 |
| WEST PALM BEACH, FL.33402 |
| [email protected] |
| P: 561-805-6692 |
| F: 561-805-6676 |
| |
| |
| |
| |
| |