2020-06-12 15:04:07 | PLAN REVIEW - BUILDING |
| |
| CODES IN EFFECT: |
| 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| CHAPTER 1 ADMINISTRATION |
| |
| CHRISTOPHER S. THROOP, C.B.O. |
| PLANS EXAMINER BUILDING - PX3169 |
| PLANS EXAMINER 1&2 FAMILY - SFP306 |
| CONSTRUCTION SERVICES DIVISION |
| TEL: 561-805-6726 |
| FAX: 561-805-6676 |
| E-MAIL: [email protected] |
| |
| 2ND REVIEW |
| |
| RESULTS: DENIED |
| |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| |
| PREVIOUS COMMENTS THAT HAVE BEEN ADDRESSED |
| SATISFACTORILY ARE MARKED AS CORRECTED. |
| PREVIOUS COMMENTS THAT HAVE NOT BEEN ADDRESSED |
| SATISFACTORILY HAVE ADDITIONAL COMMENTS IN PARENTHESES. |
| ANY NEW COMMENT WILL BE LISTED AFTER PREVIOUS COMMENTS. |
| |
| |
| NOTICE: THE PROPOSED STRUCTURES ARE LOCATED IN A |
| SPECIAL FLOOD HAZARD AREA (SFHA) WITH A BASE FLOOR |
| ELEVATION (BFE) OF 7.0 FEET NAVD. BUILDINGS AND |
| STRUCTURES LOCATED IN SFHA'S SHALL BE DESIGNED PER FBC |
| R322. |
| |
| R322.1.2STRUCTURAL SYSTEMS. |
| STRUCTURAL SYSTEMS OF BUILDINGS AND STRUCTURES SHALL BE |
| DESIGNED, CONNECTED AND ANCHORED TO RESIST FLOTATION, |
| COLLAPSE OR PERMANENT LATERAL MOVEMENT DUE TO |
| STRUCTURAL LOADS AND STRESSES FROM FLOODING EQUAL TO |
| THE DESIGN FLOOD ELEVATION. |
| |
| 1. SITE PLAN. CORRECTED |
| |
| 2. FOUNDATIONS FOR WALLS AND COLUMNS AT PROPERTY LINE |
| SHALL NOT ENCROACH ONTO ADJOINING PROPERTY. PROVIDE |
| STRUCTURAL DETAIL FOR FOUNDATIONS. |
| 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| (NOTE ON PLAN PAGE L2 STATES FACE OF WALL WILL BE 6 |
| INCHES INSIDE PROPERTY LINE. WALL TYPE 1 PAGE AL-1 |
| ALONG N FLAGLER DRIVE HAS A 24 INCH FOUNDATION WITH AN |
| 8 INCH WALL. THIS FOUNDATION WILL ENCROACH ONTO |
| ADJACENT PROPERTY) |
| |
| 3. NOTE ON PLAN STATES SLIDING GATES WILL BE MOTORIZED. |
| PROVIDE ELCTRICAL PLAN. (NOT APPLICABLE - SEE PERMIT |
| 20040727 FOR GATES) |
| |
| |
| |