Date |
Text |
2020-04-15 10:00:47 | CHANGE OF OCCUPANCY |
| REVIEWED BY ROGER MCPHERSON |
| 561-805-6716 |
| [email protected]. |
| |
| CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 |
| 1) PLEASE SHOW THE OCCUPANCY CLASSIFICATION PER FBC |
| CHAPTER 3. |
| 2) PLEASE PROVIDE A LIFE SAFETY PLAN SHOWING MEANS OF |
| EGRESS FBC CHAPTER10, FIRE SPRINKLERS FBC 420.5, FIRE |
| ALARMS AND SMOKE ALARMS FBC 420.6 ETC. |
| 3) PLEASE SHOW THE NUMBER OF OCCUPANTS. |
| 4) PLEASE SHOW THE FIRE RATING OF THE SEPARATION WALLS |
| TO COMPLY WITH FBC 420.2 |
| 5) PLEASE DESCRIBE THE USE FOR THE BUILDING - WHAT ARE |
| THE OCCUPANTS THERE FOR? |
| |
| GROUP R-4 OCCUPANCIES SHALL MEET THE REQUIREMENTS FOR |
| CONSTRUCTION AS DEFINED FOR GROUP R-3, EXCEPT AS |
| OTHERWISE PROVIDED FOR IN THIS CODE OR SHALL COMPLY |
| WITH THE FLORIDA BUILDING CODE, RESIDENTIAL PROVIDED |
| THE BUILDING IS PROTECTED BY AN AUTOMATIC SPRINKLER |
| SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.2.8. |
| |
| 310.6.1CONDITION 1. |
| THIS OCCUPANCY CONDITION SHALL INCLUDE BUILDINGS IN |
| WHICH ALL PERSONS RECEIVING CUSTODIAL CARE, WITHOUT ANY |
| ASSISTANCE, ARE CAPABLE OF RESPONDING TO AN EMERGENCY |
| SITUATION TO COMPLETE BUILDING EVACUATION. 310.6.2 |
| CONDITION 2. THIS OCCUPANCY CONDITION SHALL INCLUDE |
| BUILDINGS IN WHICH THERE ARE ANY PERSONS RECEIVING |
| CUSTODIAL CARE WHO REQUIRE LIMITED VERBAL OR PHYSICAL |
| ASSISTANCE WHILE RESPONDING TO AN EMERGENCY SITUATION |
| TO COMPLETE BUILDING EVACUATION. |
| |
| 310.6.2CONDITION 2. |
| THIS OCCUPANCY CONDITION SHALL INCLUDE BUILDINGS IN |
| WHICH THERE ARE ANY PERSONS RECEIVING CUSTODIAL CARE |
| WHO REQUIRE LIMITED VERBAL OR PHYSICAL ASSISTANCE WHILE |
| RESPONDING TO AN EMERGENCY SITUATION TO COMPLETE |
| BUILDING EVACUATION. |