Plan Review Notes For Permit 20031388 |
Permit Number |
20031388 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2020-04-03 10:30:47 | ROOFING | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected]. | | | | CORRECTIONS NEEDED - FBC WPB AMENDMENTS 107 | | 1) PLEASE CIRCLE THE ITEMS TO BE USED IN THE PRODUCT | | APPROVALS (ROOFING TILE, SYSTEM, ATTACHMENT ETC.) | | 2) PLEASE SHOW THE BUILDING HEIGHT. | | 3) PLEASE SHOW THE ROOF SLOPE. | | 4) PLEASE SHOW A MECHANICALLY ATTACHED BASE SHEET PER | | FBC RAS 120 ---- 1) ASTM D226 TYPE II #30 OR ASTM D2626 | | (#43) INORGANIC BASE NAILED TO DECK, MIN ASTM D6380, | | CLASS M OR WS, TYPE II (#90) ORGANIC CAP SHEET SET IN | | TYPE IV HOT ASPHALT. -------------OR----------- | | 2) ANY PRODUCT APPROVED UNDERLAYMENT SYSTEM WITH A | | MECHANICALLY FASTENED BASE SHEET, AND CAP SHEET SET | | HOT, COLD, OR SELF ADHERED. | | | | | | |
|