Date |
Text |
2022-05-02 11:57:41 | FAILED |
| |
| PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS. |
| |
| ARCADE IDENTITY SIGN |
| |
| 1) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT A |
| MAXIMUM LETTER HEIGHT OF 18 INCHES FOR A ARCADE |
| IDENTITY SIGN. WHILE THIS IS VERIFIED FOR THE "C", YOU |
| NEED TO PROVIDE THE HEIGHT OF THE "P". |
| |
| 2) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| THAT RIVETS, SCREWS AND OTHER FASTENERS THAT EXTEND TO |
| VISIBLE SURFACES SHALL BE FLUSH, FILLED AND FINISHED SO |
| AS TO BE UNNOTICEABLE. THE BOLT HEADS THAT EXTEND PAST |
| THE MOUNTING PLATE DO NOT MEET THIS STANDARD. IF THE |
| BOLT HEADS MUST EXTEND PAST THE MOUNTING PLATE, THEY |
| NEED TO BE CONCEALED BY CAPS MATCHING THE COLOR OF THE |
| MOUNTING PLATE. |
| |
| 3) THE ROSEMARY SQUARE TENANT SIGN CRITERIA ONLY PERMIT |
| WHITE ACRYLIC FOR PUSH THROUGH APPLICATIONS AND DO NOT |
| SPECIFICALLY PERMIT IT AS A SIGN FACE; THEREFORE, THIS |
| USE OF ALTERNATIVE MATERIALS ON THE SIGN REQUIRES A |
| WAIVER I WRITTEN APPROVAL FROM CITYPLACE RETAIL TO BE |
| SUBMITTED WITH THE PERMIT. |
| |
| 4) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| THAT THE LETTERS ARE TO BE FABRICATED OUT OF ALUMINUM |
| WITH A MINIMUM METAL THICKNESS OF .060 INCHES WITH A |
| PAINTED FINISH. THE SIGN DETAIL SHOWS THAT THE LETTER |
| BACKS ARE 0.125 INCHES THICK DIBOLD. THIS DOES NOT |
| VERIFY THAT THE ALUMINUM COMPONENT IS .060 INCHES |
| THICK, NOR IS THE DIBOLD MATERIAL PERMITTED. THIS USE |
| OF ALTERNATIVE MATERIALS ON THE SIGN REQUIRES A WAIVER |
| I WRITTEN APPROVAL FROM CITYPLACE RETAIL TO BE |
| SUBMITTED WITH THE PERMIT. NO INFORMATION IS PROVIDED |
| TO SHOW THAT THE RETURNS MEET THE ROSEMARY SQUARE |
| TENANT SIGN CRITERIA. |
| |
| 5) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE ALL |
| CONDUIT, RACEWAYS, WIRING, BALLAST BOXES, TRANSFORMERS, |
| JUNCTION BOXES, BELL BOXES, POWER SUPPLY AND OTHER |
| EQUIPMENT NECESSARY FOR SIGN CONNECTION SHALL BE |
| CONCEALED AND NOT VISIBLE TO THE PUBLIC. THE PERMIT |
| DRAWINGS SHOW THE 3/4 INCH DIAMETER EMT CONDUIT NOT |
| MEETING THIS REQUIREMENT SINCE EXPOSED CONDUIT IS |
| ATTACHED TO THE INSIDE OF THE ARCADE. |
| |
| BLADE SIGN |
| |
| 6) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE |
| THAT COPY AREA BE AT LEAST 3 INCHES FROM ANY EDGE OF |
| THE PERCEIVED SIGN AREA. PROVIDE DIMENSIONS FROM THE |
| COPY TO THE EDGE OF THE SIGN SO THAT STAFF CAN VERIFY |
| COMPLIANCE. |
| |
| 7) THE PLAN VIEW SHOW TWO DIFFERENT DIMENSIONS FOR THE |
| SIGN ELEMENTS - 24 INCHES AND 23.5 INCHES. ALL DRAWINGS |
| MUST SHOW THE SAME, ACCURATE DIMENSIONS. |
| |
| 8) THE ROSEMARY SQUARE TENANT SIGN CRITERIA DO NOT |
| PERMIT THE APPLIED VINYL ON THE FACE OF THE SIGN UNLESS |
| THE USE OF ALTERNATIVE MATERIALS ON THE SIGN IS |
| APPROVED AS A WAIVER I WRITTEN APPROVAL FROM CITYPLACE |
| RETAIL AND SUBMITTED WITH THE PERMIT. |
| |
| NOTE: YOU WERE ASSESSED A 4 TIMES THE FEE PENALTY FOR |
| INSTALLING THE SIGNS WITHOUT A PERMIT. |
| |
| CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| [email protected] |
| |