Plan Review Notes
Plan Review Notes For Permit 20031379
Permit Number 20031379
Review Stop Z
Sequence Number 1
Notes
Date Text
2020-04-24 15:39:45FAILED
  
 PLEASE PROVIDE WRITTEN RESPONSES TO COMMENTS.
  
 PROVIDE DRAWIGS WHICH ARE MORE LEGIBLE.
  
 ARCADE IDENTITY SIGN
  
 1) STAFF IS UNABLE TO DETERMINE WHAT THE SIGN LOOKS
 LIKE FROM THE DRAWINGS THAT ARE PROVIDED, SINCE TWO
 DIFFERENT DESIGNS ARE SHOWN.
  
 A. THE STOREFRONT ELEVATION 2 DRAWING APPEARS TO HAVE
 THE TENANT NAME MOUNTED TO A PANEL THAT IS SOMEHOW
 SUSPENDED FROM THE TOP OF THE ARCADE. THE METHOD OF
 ATTACHMENT TO THE TOP OF THE ARCADE IS UNCLEAR, SO
 STAFF IS UNABLE TO DETERMINE IF IT COMPLIES WITH THE
 ROSEMARY SQUARE TENANT SIGN CRITERIA. ADDITIONALLY,
 SINCE NO PLANS DEPICTING THE METHOD OF CONSTRUCTION
 WERE PROVIDED, STAFF CANNOT DETERMINE IF THE ROSEMARY
 SQUARE TENANT SIGN CRITERIA FABRICATION REQUIREMENTS
 ARE MET.
  
 B. THE SIGNED ENGINEERING PLANS SHOW CHANNEL LETTERS
 MOUNTED TO AN ALUMINUM TUBE. THIS DESIGN DOES NOT MATCH
 ARCADE IDENTITY SIGN OPTION 2A SUSPENDED LETTERS ON A
 RACEWAY THAT IS DEPICTED IN THE ROSEMARY SQUARE TENANT
 SIGN CRITERIA.
  
 2) ONCE ONE DESIGN IS SUBMITTED, ZONING COMMENTS WILL
 BE ISSUED FOR THAT SIGN. AS PROVIDED, EACH DESIGN HAS
 NUMEROUS CONFLICTS WITH THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA. EACH DESIGN HAS MULTIPLE ITEMS THAT ARE NOT
 ADDRESS OR DO NOT COMPLY WITH THE ROSEMARY SQUARE
 TENANT SIGN CRITERIA. PLEASE REVIEW THE ROSEMARY SQUARE
 TENANT SIGN CRITERIA BEFORE YOU RESUBMIT TO VERIFY THAT
 THE SIGN DESIGN YOU CHOOSE MEETS THE CRITERIA AND
 PROVIDES THE INFORMATION NEEDED TO REVIEW THE PERMIT.
  
 BLADE SIGN
  
 3) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 BLADE SIGNS TO BE SUSPENDED ON A METAL BRACKET, NOT
 FLUSH MOUNTED TO THE WALL.
  
 4) BLADE SIGNS ARE ONLY PERMITTED TO HAVE THE TRADE
 NAME AND/OR LOGO MARK ONLY. THE "SLEEP STORE" TEXT IS
 NOT PERMITTED UNLESS CITYPLACE RETAIL PROVIDES WRITTEN
 APPROVAL AS A WAIVER I. THE WRITTEN APPROVAL MUST BE
 INCLUDED WITH THE PERMIT RESUBMITTAL.
  
 5) THE ROSEMARY SQUARE TENANT SIGN CRITERIA STATES THAT
 WALL MOUNTED BLADE SIGN PANELS SHALL BE DOUBLE SIDED
 WITH A MAXIMUM SIGN FACE OF FOUR (4) SQUARE FEET PER
 SIDE. THE PROPOSED SIGN FACE EXCEEDS THIS AT 29.825
 INCHES ON A SIDE. NOTE: THE PLANS SHOW TWO DIFFERENT
 DIMENSIONS FOR THE SIGN ELEMENTS. ALL DIMENSIONS MUST
 BE THE SAME.
  
 6) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT THE LETTERS ON A BLADE SIGN BE PUSH-THROUGH WHITE
 ACRYLIC LETTERS.
  
 A. THE MATERIALS KEY INCLUDES M-2: 1/2 INCH WHITE
 ACRYLIC PUSH THRU, HOWEVER THIS KEY NOTE IS NOT
 INCLUDED WITH THE SIGN ITSELF. IT DOES SHOW M-3 AND
 M-4, WHICH ARE WHITE ACRYLIC, BUT DO NOT SPECIFY THAT
 THESE LETTERS ARE PUSH-THROUGH. THE M-3 NOTATION ON THE
 PLAN STATES THAT THE TEXT IS ROUTED & BACKED COPY,
 WHICH IS NOT PUSH-THROUGH.
  
 B. NOTE V1 ORACLE 052 AZURE BLUE IS SHOWN POINTING TO
 THE LETTER "R". THE ROSEMARY SQUARE TENANT SIGN
 CRITERIA ONLY PERMIT WHITE LETTERS.
  
 7) THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT
 CITYPLACE RETAIL TO GRANT A WAIVER I TO USE ALTERNATE
 MATERIALS FROM THOSE SPECIFIED IN THE MASTER SIGN PLAN.
 A WAIVER I MUST BE GRANTED IN WRITING BY CITYPLACE
 RETAIL AND SUBMITTED WITH THE PERMIT RESUBMITTAL.
  
 8) THE ROSEMARY SQUARE TENANT SIGN CRITERIA REQUIRE
 THAT COPY AREA BE AT LEAST 6 INCHES FROM ANY EDGE OF
 THE PERCEIVED SIGN AREA. PROVIDE VERIFICATION ON THE
 PLAN.
  
 BANNER
  
 9) TEMPORARY BANNERS ARE NOT PERMITTED TO BE MOUNTED TO
 THE WALL. ADDITIONALLY, SINCE YOU ARE PROPOSING AN
 ARCADE IDENTITY SIGN, YOU ARE NOT PERMITTED TO HAVE A
 FASCIA SIGN.
  
 CONTACT ERIC SCHNEIDER @ (561) 822-1446