2020-05-23 14:22:14 | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | BUILDING REVIEW DENIED: | | | | 1. FBC B 107.3.4.1. PLEASE ADD TO THE DEFFERED | | SUBMITTAL SECTIONS OF PAGES ALS 1.1 AND 1LS 2.1: | | A) SHOP DRAWINGS FOR EXTERIOR LIGHT GAGE FRAMING | | MATERIAL | | B) EXTERIOR WALL CLADDING PRODUCT APPROVALS/DETAILS | | C) INTUMESCENT PAINT PRODUCT APPROVALS/MANUFACTURER'S | | SPECIFICATIONS | | | | 2. FBC B 107, FBC B 108, PLEASE PROVIDE RESPONSE TO THE | | PRIOR BUILDING REVIEW COMMENT REGARDING THRESHOLD | | INSPECTOR REQUIREMENTS. |
|