Date |
Text |
2021-03-24 11:00:56 | FAILED |
| |
| PROVIDE WRITTEN RESPONSES TO COMMENTS. |
| |
| THE SIGN IS AN ARCADE IDENTITY SIGN TYPE 1D. |
| |
| 1) THE PLAN SUBMITTAL HAS TWO CONFLICTING STYLE |
| VERSIONS OF THE SIGN INSTALLATION THAT HAVE AN UPLOAD |
| DATE OF FEBRUARY 25, 2021. ONE VERSION COMPLIES WITH |
| THE ROSEMARY SQUARE TENANT SIGN CRITERIA. STAFF CANNOT |
| MOVE THE PERMIT FORWARD WITH CONFLICTING DRAWINGS, NOR |
| CAN A FULL ANALYSIS BE PROVIDED. |
| |
| A. THE VERSION THAT SHOWS TWO RACEWAYS SPANNING BETWEEN |
| THE VERTICAL ARCADE COLUMNS MEETS THE ARCADE IDENTITY |
| SIGN TYPE (OPTION D) MOUNTING CRITERIA; HOWEVER, THE |
| DETAILS OF THE ATTACHMENT AND THE FABRICATION WERE NOT |
| PROVIDED. |
| |
| B. THE VERSION THAT SHOWS TWO RACEWAYS SUSPENDED BY |
| VERTICAL SUPPORTS FROM THE CEILING DOES NOT MEET THE |
| ARCADE IDENTITY SIGN TYPE MOUNTING CRITERIA AND IS NOT |
| PERMITTED. NOTE: THIS IS THE SAME DESIGN THAT HAS BEEN |
| PREVIOUSLY SUBMITTED AND STAFF HAS PROVIDED COMMENTS |
| THAT IT DOES NOT COMPLY WITH THE ROSEMARY SQUARE TENANT |
| SIGN CRITERIA. |
| |
| 2) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN |
| CRITERIA REQUIRE THAT ARCADE IDENTITY SIGNS HAVE A |
| MINIMUM CLEARANCE OF NINE (9) FEET FROM FINISHED GRADE. |
| PLEASE PROVIDE THE DIMENSION ON THE ELEVATION DRAWING. |
| THE PROVIDED DIMENSION OF 12 FEET TO THE TOP OF THE |
| SIGN IS REQUIRED AND COMPLIES WITH THE ROSEMARY SQUARE |
| TENANT SIGN CRITERIA. |
| |
| 3) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN |
| CRITERIA REQUIRE THAT ARCADE IDENTITY SIGN LETTERS BE |
| INTERNALLY ILLUMINATED UNLESS THE SIGN STYLE IS A PANEL |
| MOUNT, WHICH NEITHER OF THE VERSIONS SHOW. THE ROSEMARY |
| SQUARE TENANT SIGN CRITERIA DO NOT PERMIT A WAIVER FOR |
| THIS REQUIREMENT FOR ARCADE IDENTITY SIGNS. PLEASE NOT |
| THAT THE BARIO SIGN THAT IS REFERENCED WAS APPROVED |
| UNDER THE PREVIOUS MASTER SIGN PLAN THAT NO LONGER |
| APPLIES. |
| |
| 4) PLEASE REMEMBER THAT THE ROSEMARY SQUARE TENANT SIGN |
| CRITERIA REQUIRE THAT REQUIRE THAT ALL CONDUIT, |
| CROSSOVERS, WIRING NECESSARY FOR THE SIGN'S ELECTRICAL |
| CONNECTION TO BE CONCEALED AND NOT VISIBLE TO THE |
| PUBLIC. THIS INCLUDES THE ELECTRICAL PRIMARY TO THE |
| SIGN, WHICH MUST BE SHOWN ON THE PLANS. |
| |
| 5) REPEAT COMMENT: THE ROSEMARY SQUARE TENANT SIGN |
| CRITERIA REQUIRE ARCADE IDENTITY SIGNS TO BE CENTERED |
| HORIZONTALLY UNDER THE ARCADE ARCHWAY. PROVIDE THE |
| DIMENSIONS FROM THE ARCADE COLUMNS TO VERIFY THAT THE |
| SIGN IS CENTERED. |
| |
| SIGN SF |
| |
| PERMITTED: 25 SF |
| PROPOSED: 7.2 SF |
| |
| CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| [email protected] |
| |