2020-10-13 10:42:20 | FAILED |
| |
| 1) THE PROPOSED SIGN IS A CANOPY SIGN IN THE ROSEMARY |
| SQUARE TENANT SIGN CRITERIA. THE PERMIT FOR THE CANOPY |
| (TRELLIS) ON WHICH THIS SIGN IS TO BE MOUNTED DID NOT |
| PASS ITS PERMIT REVIEW. PLEASE REFER TO PERMIT 20080636 |
| FOR THE SPECIFIC COMMENTS. ZONING WILL NOT APPROVE THIS |
| PERMIT UNTIL SUCH TIME AS THE CANOPY PERMIT IS |
| APPROVED. |
| |
| 2) THE RESUBMITTED DRAWINGS INCLUDE TWO DIFFERENT SIGN |
| CONFIGURATIONS. |
| |
| A. ONE IS THE SAME AS THE SAME AS THE ONE THAT STAFF |
| PREVIOUSLY ISSUED THE FOLLOWING COMMENTS: |
| |
| THE SIGN INCLUDES REVERSE CHANNEL LETTERS ABOVE THE |
| CANOPY WITH THE POWER SUPPLY BOX (RACEWAY) ON TOP OF |
| THE CANOPY BEHIND THE LETTERS. THIS IS NOT A PERMITTED |
| OPTION FOR A CANOPY SIGN. THE ROSEMARY SQUARE TENANT |
| SIGN CRITERIA SPECIFIES LETTERS MAY BE MOUNTED WITHIN |
| THE VERTICAL FACE OF THE CANOPY, INDIVIDUAL METAL |
| LETTERS MAY BE PIN MOUNTED ABOVE OR BELOW THE CANOPY |
| (WITH AMBIENT ILLUMINATION PERMITTED), OR INTEGRATED |
| INTO THE HORIZONTAL PLANE OF THE CANOPY AS PART OF THE |
| CANOPY. ADDITIONALLY, THE ROSEMARY SQUARE TENANT SIGN |
| CRITERIA PROHIBIT EXPOSED RACEWAYS. NOTE: REGARDLESS OF |
| THE FINAL SIGN DESIGN, THE CANOPY NEEDS TO BE DESIGNED |
| TO INCORPORATE THE POWER SUPPLY, CONDUIT, ETC. WITHIN |
| IT FOR ANY SIGNAGE THAT WILL BE MOUNTED ON THE CANOPY. |
| |
| THE ROSEMARY SQUARE TENANT SIGN CRITERIA PERMIT A |
| MAXIMUM LETTER HEIGHT OF 18 INCHES FOR A CANOPY SIGN |
| UNLESS CITYPLACE RETAIL IS GRANTED A WAIVER II (MINOR |
| PLANNED DEVELOPMENT AMENDMENT). THE WAIVER II MAY |
| INCREASE THE SIGNS DIMENSION BY UP TO 25 PERCENT, SO |
| THE LETTER HEIGHT COULD THEN BE 19 INCHES TALL AS |
| SHOWN. |
| |
| B. THE NEW SIGN CONFIGURATION DOES NOT PROVIDE ALL THE |
| INFORMATION REQUIRED TO PROVIDE A FULL REVIEW; HOWEVER, |
| IT STILL DOES NOT COMPLY WITH ANY OF THE THREE OPTIONS |
| PROVIDED IN THE ROSEMARY SQUARE TENANT SIGN CRITERIA |
| (LISTED IN COMMENT 2A ABOVE). |
| |
| 3) THE NEW SIGN DRAWING SHOWING THE SERVICE TRAPS AND |
| THE POWER SUPPLY SHOWN IN THE CANOPY (TRELLIS) DO NOT |
| EXIST ON THE CANOPY PERMIT. THESE CANNOT JUST BE CUT IN |
| AFTER THE FACT AS THEY MAY AFFECT THE STRUCTURAL |
| INTEGRITY OF THE CANOPY AND NEGATE THE ENGINEERING |
| APPROVAL OF THE CANOPY. ADDITIONALLY, THE PLANS STATE |
| THAT THE ELECTRICAL PRIMARY TO THE SIGN IS BY OTHERS. |
| NO PERMIT HAS BEEN SUBMITTED FOR THIS ELECTRICAL WORK. |
| |
| PERMITTED: 38.1 SF |
| PROPOSED: 19.2 SF (VERIFICATION REQUIRED) |
| |
| CONTACT ERIC SCHNEIDER @ (561) 822-1446 |