Plan Review Notes For Permit 20030297 |
Permit Number |
20030297 |
|
Review Stop |
B |
Sequence Number |
1 |
|
Notes |
Date |
Text |
2020-03-07 13:59:29 | ***CORRECTIONS*** | | PETER E VALENTI | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6673 | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | FBC M = FBC MECHANICAL | | | | BUILDING REVIEW DENIED: | | | | FBC B 107.2.1, PLEASE PROVIDE THE DESIGN PROFESSIONAL | | APPROVED ENHANCED FASTENING PATTERN AND CALCULATIONS | | FOR THE ZONE 2 PERIMETER AND ZONE 3 CORNERS OF THIS | | ROOF AS PER GENERAL LIMITATIONS OF THE PRODUCT APPROVAL | | # 18-0919.08. |
|