Date |
Text |
2020-03-27 17:31:21 | 1ST REVIEW FBC-2017 MECHANICAL |
| PERMIT #20030166 |
| 3/27/20 |
| |
| CODES IN EFFECT: |
| |
| FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017 |
| FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017 |
| FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION |
| 2017 |
| FBC FG- FLORIDA FUEL GAS CODE SIXTH EDITION 2017 |
| FBC EX- FLORIDA EXISTING BUILDING CODE SIXTH EDITION |
| 2017 |
| FS- FLORIDA STATUTES |
| FAC- FLORIDA ADMINISTRATIVE CODE |
| WPB- WEST PALM BEACH AMENDMENTS TO THE FBC SIXTH |
| EDITION 2017 |
| |
| PLAN REVIEW RESULTS: DENIED. |
| |
| 1) SHEET H-1: THE NOTES INDICATE THE APPLICABLE |
| COMPLIANCE CODE SECTIONS FROM THE FLORIDA MECHANCIAL |
| CODE- 2014 FIFTH EDITION FOR NON-LISTED COMMERCIAL |
| KITCHEN HOOD, HOWEVER THERE IS NO EVIDENCE ON THE PLAN |
| THAT THE HOOD TO BE INSTALLED MEETS THOSE COMPLIANCES |
| ORE THE 2017 APPLICABLE CODE SECTIONS. PLEASE UP DATE |
| THE CODE SECTIONSIN THE NOTES AND PROVIDE A SCHEMATIC |
| DRAWING OF THE HOOD AND A EQUIPMENT SCHEDULE THAT |
| INDICATES COMPLIANCE WITH SECTIONS 507.1.5, 507.2.3, |
| 507.2.5, 507.2.8, & 507.4, & 507.5 FBC M. |
| |
| 2) H-1: INDICATE COMPLIANCE WITH SECTION 508.1.1 FBC M |
| WHICH REQUIRES THE TEMPERATURE DIFFERENTIAL BETWEEN THE |
| MAKEUP AIR AND THE AIR IN THE CONDITIONED SPACE TO NOT |
| EXCEED 10 DEGREES F. |
| |
| 3) H-1: SHOW THE REQUIRED 18" CLEARANCE TO COMBUSTIBLES |
| FOR THE GREASE EXHAUST DUCT INCLUDING THE PENETRATION |
| THROUGH THE ROOF- SECTION 506.3.6 FBC M. |
| |
| 4) H-1: SHOW THE REQUIRED 18" CLEARANCE TO COMBUSTIBLES |
| FOR THE GREASE HOOD IN COMPLIANCE WITH SECTION 507.2.6 |
| FBC M. IF COMPLYING WITH THE EXCEPTION, PLEASE PROVIDE |
| HOOD BACKING DIMENSIONS ON THE DRAWING TO SHOW PROPER |
| EXTENSION COVERAGE. |
| |
| 5) THE $12,900.00 VALUE ON THE APPLICATION APPEARS LOW |
| FOR THE ENTIRE SCOPE OF WORK. PLEASE PROVIDE COPIES AOF |
| SIGNED CONTRACTS AND/OR ESTIMATES, INVOICES ETC. TO |
| VERIFY THE TOTAL COST. PLEASE NOTE THAT PERMIT VALUE IS |
| BASED ON LABOR, MATERIALS AND EQUIPMENT- SECTION 109.3 |
| WPB. |
| |
| WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT |
| CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE OLD |
| SHEETS FROM THE PLAN SETS, BIND THEM TOGETHER |
| SEPARATELY AND MARK VOID OR OLD ON THEM. PLEASE RETAIN |
| THEM FOR REFERENCE WITH THE NEW SUBMITTED PLANS. THIS |
| PROCESS WILL ALSO APPLY TO ANY DOCUMENTS SUCH AS |
| PRODUCT APPROVALS OR CALCULATIONS BEING REPLACED OR |
| UPDATED. |
| |
| CHRISTOPHER L. COLE |
| MECHANICAL PLANS EXAMINER |
| 401 CLEMATIS STREET |
| WEST PALM BEACH FL 33401 |
| 561-805-6719 |
| [email protected] |
| |