Date |
Text |
2020-04-16 11:28:24 | INCOMPLETE APPLICATION |
| |
| PERMIT 20030142 - UNDERGROUND FIBER MCIMETRO PROJECT |
| #1806CQCB.18 100 BLOCK DATURA ST. |
| |
| PROVIDE WRITTEN RESPONSE TO COMMENTS. |
| |
| PLEASE SEE THE LIST BELOW FOR AN ANALYSIS OF THE |
| DEFICIENCIES IN INFORMATION REQUIRED BY SECTION 78-401 |
| OF THE CITY OF WEST PALM BEACH CODE AS PART OF THE |
| COMMUNICATION FACILITIES PLACEMENT PERMIT APPLICATION. |
| THE DEFICIENT INFORMATION MUST BE PROVIDED FOR STAFF TO |
| REVIEW THE PERMIT APPLICATION. PLEASE NOTE THAT STAFF |
| HAS ALSO INCLUDED SOME SUBSTANTIVE REVIEW COMMENTS, |
| THAT WHILE NOT RESULTING IN A DEFICIENT APPLICATION, |
| NEED TO BE ADDRESSED OR THE PERMIT WILL NOT BE |
| APPROVED. |
| |
| 1) UPDATED COMMENT: SURVEY - THE SURVEY DOES NOT SHOW |
| SUFFICIENT INFORMATION FOR STAFF TO VERIFY WHAT IS |
| SHOWN ON THE ENGINEERING PLANS. |
| |
| A. THE SURVEY MUST BE PROVIDED AT A LEGIBLE SCALE AND |
| CLEARLY SHOW THE RIGHT-OF-WAY LINE AND THE SIDEWALK. |
| |
| B. ALL UNDERGROUND UTILITIES NEED TO BE SHOWN ON THE |
| SURVEY. IF THE BORE IS PROPOSED WITHIN FIVE (5) FEET OF |
| AN EXISTING UTILITY, YOU NEED TO PROVIDE A LETTER FROM |
| THAT UTILITY THAT THE PROPOSED BORE DOES NOT INTERFERE |
| WITH THE PROVISIONS OF THEIR SERVICES. NONE OF THE |
| PREVIOUSLY SUBMITTED UTILITY LETTERS COVER THIS PORTION |
| OF THE FIBER INSTALL. |
| |
| C. THE LOCATIONS OF THE TREES WITHIN 20 FEET OF THE |
| EXISTING AND PROPOSED HANDHOLES AND THE PROPOSED TIE |
| INS NEED TO BE SHOWN ON THE SURVEY. THE ENGINEERING |
| PLAN NEEDS TO SHOW THE TREES AND A TEN (10) FOOT |
| SETBACK FROM THE TREES TO THE HANDHOLES AND TIE INS IN |
| ORDER TO PREVENT DAMAGE TO THE TREES OR THEIR ROOT |
| ZONES FROM BOTH THE BORE AND THE HANDHOLE INSTALLATION. |
| WHERE THE BORE IS SHOWN AT TEN (10) FEET BELOW GRADE IT |
| IS AT A SUFFICIENT DEPTH TO AVOID DAMAGING THE ROOT |
| ZONES; HOWEVER, STAFF NEEDS TO BE ABLE TO REVIEW THE |
| LOCATIONS WHERE IT TRANSITIONS UP TO THE HANDHOLES AND |
| THE TIE INS TO VERIFY THAT THERE IS NO ROOT ZONE |
| DAMAGE. |
| |
| D. THE ENGINEERING PLANS MUST SHOW THE SAME CONDITIONS |
| AS THE SURVEY, SO THAT STAFF CAN VERIFY THAT NONE OF |
| THE PROPOSED WORK IS BEING INSTALLED ON PRIVATE |
| PROPERTY. |
| |
| 2) ENGINEERING PLAN - SHOW THE DIMENSION FROM THE |
| FLAGLER DRIVE LIGHT POLE TO THE BORE SO THAT STAFF CAN |
| VERIFY THAT THE LIGHT POLE FOUNDATION WILL NOT BE |
| AFFECTED BY THE BORE. |
| |
| 3) UPDATED COMMENT: EVIDENCE OF INSURANCE COVERAGE |
| |
| A. SINCE THE COMMUNICATIONS FACILITIES PLACEMENT PERMIT |
| APPLICATION LISTS MCIMETRO ACCESS TRANSMISSION SERVICES |
| CORP AS THE REGISTRANT, THIS IS WHOSE CERTIFICATE OF |
| LIABILITY INSURANCE NEEDS TO BE PROVIDED. |
| |
| B. THE CERTIFICATE OF LIABILITY INSURANCE NEEDS TO BE |
| REVISED TO NAME THE CITY OF WEST PALM BEACH, ITS |
| COMMISSIONERS, OFFICERS, EMPLOYEES AND AGENTS AS |
| ADDITIONAL INSURED. |
| |
| C. THE CERTIFICATE HOLDER IS THE ENGINEERING SERVICES |
| DEPARTMENT. |
| |
| 4) POLE STYLE - PLEASE NOTE THAT THE FUTURE POLES ARE |
| REQUIRED TO MEET THE CITY CONCEALMENT STANDARDS |
| OUTLINED IN SECTION 78-411 OF THE CITY CODE. |
| |
| 5) ELECTRONIC FORMAT OF SUBMITTAL - A COPY OF ALL OF |
| THE SUBMITTAL MATERIAL MUST BE SUBMITTED IN ELECTRONIC |
| FORMAT. |
| |
| CONTACT ERIC SCHNEIDER @ (561) 822-1446 |
| [email protected] |
| |