2020-03-10 11:06:26 | REVIEW COMMENTS FOR ANCHOR SPACES: |
| 1) 708.6 FBC{B]SHEET A-101 NOTE A51 STATES EXISTING TO |
| REMAIN. PLEASE STATE THE FIRE RATING OF THIS DOOR AS IT |
| IS IN A FIRE PARTITION SEPARATING THE TENANT SPACES. |
| |
| 2) 708.1 FBC[B]SHOW 1 HOUR FIRE SEPARATIONS OF TENANT |
| SPACES. |
| |
| 3) STATE ON DATA SHEET THE PREVIOUS OCCUPANCY OF ANCHOR |
| SPACES. |
| |
| 4) PROVIDE BREAKDOWN OF SQUARE FOOTAGES OF EACH SPACE. |
| |
| 5) SHEET G-103B PLEASE CHANGE THE CONSTRUCTION TYPE |
| LISTED IN -TYPES OF CONSTRUCTION-(A) CH. 6- LAST COLUMN |
| TO TOP ROW SAYS TYPE 2B. |
| MATCH THE TYPE STATED ON THE FIRST COLUMN (TYPE 1-B) |
| |
| 6) 705.8 TABLE FBC[B]SHOW FIRE SEPARATION BETWEEN THE |
| NEW PARKING GARAGE AND EXISTING STRUCTURE TO THE SOUTH. |
| USE BUILDING TO PROPERTY LINES AS THE SEPARATION |
| DISTANCE. STATE THE ALLOWABLE AREA OF OPENINGS BASED ON |
| THE SEPARATION DISTANCE. |
| |
| 7) 1011.12 FBC[B]SHEET A-106 SHOWS ROOF HATCH AT 3 FEET |
| BY 3 FEET. SEE FBC 1011.12 AND 1011.12.1 FOR REQUIRED |
| SIZE OF ROOF HATCH. |
| |
| PROVISOS: NO RESPONSE NEEDED FOR PROVISOS THEY WILL BE |
| ADDED TO PLANS BEFORE BEING ISSUED. |
| A) PROVIDE PRODUCT APPROVAL FOR ROOF HATCH AND LADDER |
| WITH 16 SQ. FT MINUMUM OPENING |
| AS REQUIRED BY FBC 1011.12 AND 1011.12.1 |
| B) ENGINEERING FOR HANDRAILS AND GUARDRAILS. |
| C) SUBMITTAL TO INCLUDE ANY PRODUCT APPROVALS INCLUDING |
| WINDOWS, STOREFRONT AND DOORS. |
| D) ROOFING PRODUCT APPROVALS TO BE SUBMITTED WITH SUB |
| PERMIT APPLICATION. |
| E) I) AIPP COMPLIANCE REQUIRED; VERIFICATION REQUIRED |
| PRIOR TO C.O. |
| CONTACT WITHIN 90 DAYS OF PERMIT ISSUANCE. |
| F) 5) CONSTRUCTION HOURS - 7AM TO 7PM MON-FRI, 8AM TO |
| 8PM SAT-SUN |
| |
| PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW |
| EACH COMMENT IS BEING ADDRESSED. |
| |